EasyPro EX11200 Manual de instalación y mantenimiento - Página 3
Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Bombas para estanques EasyPro EX11200. EasyPro EX11200 4 páginas.
PUMP END ASSEMBLY
1. Clean and inspect all pump parts (O-ring, seal seats, motor shaft, etc.).
2. Apply sealant to the bracket bore ID wall and around the seal case - follow sealant manufacturer instructions. We recommend using
Gasgacinch
. Silicone sealant can also be used.
®
3. Press carbon graphite seal into bracket while taking care not to damage carbon graphite face.
4. Place slinger (rubber washer) over motor shaft and mount bracket to motor.
5. Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain
that the ceramic is in evenly - the sealing surface should be parallel with the impeller hub.
6. Carefully lubricate carbon-graphite and ceramic sealing surfaces with CLEAN water. Do not use silicon lubricants or grease!
7. Assemble bracket to motor with four m-bolts
8. Thread impeller onto shaft and tighten! If required, remove motor end-cap and use a screwdriver on the back of motor shaft to pre-
vent shaft rotation while tightening. Replace motor end cap.
9. Seat large O-ring in volute slot and assemble volute to bracket with seven 1/4-20 x 2 3/4" hex cap screws, washers and nuts. Tighten
in a cross pattern (30 in-lbf).
10. Install drain plug with its O-ring in volute drain hole.
11. Before operating pump, allow a proper cure time for the sealant used in step 2.
VOLUTE
DRAIN PLUG
& O-RING
P-BOLT
& WASHER
DISASSEMBLY
1. Shut off power to motor before disconnecting any electrical wiring from the back of the motor.
2. Disassemble volute from bracket by removing the seven
3. Remove cap covering shaft at back of motor and with a large screwdriver, prevent shaft rotation while unscrewing impeller.
4. Remove ceramic piece from impeller. (If you are replacing the seal)
5. Detach bracket from motor.
6. Remove carbon-graphite seal from bracket by pressing out from the back. Do not dig out from the front! (If you are replacing the
seal)
EX8800 • EX11200 • EX13200
IMPELLER
SEAL
LARGE
O-RING
Reliability You Can Count On!
BRACKET
SLINGER
M-BOLT
WASHER &
LOCK NUT
2.75
/
" - 20 threads per inch x 2
1
4
DESCRIPTION
DRAIN PLUG
O-RING, DRAIN
PLUG
VOLUTE
LARGE O-RING
IMPELLER
SEAL - BRASS
SEAL - SS316
BRACKET
SLINGER
HARDWARE KIT
Note: These part numbers are only for the
standard model of EX8800. Reference page one
for impeller number.
14.75
4.22
3.50
*Motor illustration is for reference only.
/
" hex cap screws.
3
4
© 2010 EasyPro, Inc
EASYPRO
®
P/N
1000.110
E014B70
4000.070
1000.061
4000.05__*
1000.0415
1000.0414
1000.030P
1000.010V
1000.502
Pg. 3