Dickey-John CSS 110 Manual - Página 8

Navegue en línea o descargue pdf Manual para Controlador Dickey-John CSS 110. Dickey-John CSS 110 13 páginas. Automatic sprayer controller

Dickey-John CSS 110 Manual
OPERATOR'S MANUAL
Sections nozzles
C:
0
S1: 4
S2: 5
Sections nozzles
C:
0
S1: 4
S2: 5
Sections nozzles
C:
0
S1: 0
S2: 0

Nozzle pressure

1.000
bar

Nozzle flow

6.800
l/min

Flush pressure

1.000
bar
6 / SETUP

SECTION NOZZLES

Number of nozzles per section. The sections are referred to as follows:
C
S1 Left/S1 Right
S2 Left/S2 Right
S2 left
S1 left
The bars are considered symmetrical so the number of nozzles of S1 left is
equal to S1 right and S2 left to S2 right.
– Press OK to change the program and the number of nozzles per
section. If one or more sections are not present, enter 0.
Section Nozzle Examples:
5
4
NOTE: If there is only one section not connected to an electric valve
for closure, set 0 in all positions.
NOTE: In this case the CSS 110 uses the parameter and number of
nozzles to obtain the effective work width.
NOZZLE PRESSURE
Reference pressure. Program a pressure within the range of the use of the
nozzles mounted on the machine.
– Press the OK button once. The decimal point flashes to allow
moving it using the + and - buttons.
– Press the OK button to confirm and program to desired setting.
NOZZLE FLOW
Flow in volume/minute corresponding to the reference pressure taken from
the table provided by the nozzle supplier.
– Press the OK button once. The decimal point flashes to allow
moving it using the + and - buttons.
– Press the OK button to confirm and program to desired setting.
FLUSH PRESSURE
Opens valve pressure for manual control (FLUSH).
– Press the OK button once. The decimal point flashes to allow
moving it using the + and - buttons.
– Press the OK button to confirm and program to desired setting.
C
S1 right
x
0
4
CSS 110 Automatic Sprayer Controller
S2 right
5
11001-1679-201606