06 Extended Functions Menu
Additional Explanation to several menu items, page 2
The display mode switches on and off the dynamic display of several parameters during
and after the puff. The setting "cont" (continous) will display values during and 4 seconds
after the vape. With "post" the values are displayed only after the puff and off disables
the display.
The values shown depend on the operation mode: In temperature controlled mode, the parameters are
the temperature, coil resistance, temperature regulating power and a battery symbol.
For the modes power, boost and heater protection, the selected power (or limited power in case), the coil
resistance and the battery voltage are displayed. When Bypass mode is selected, the coil resistance and
the battery voltage dependent, measured power is displayed, as there is no fixed power setting in
bypass mode.
The
as short and simple as possible, 3 of the 5 modes are only available, if the Expert-Mode
is set to 1. The name is Expert-Mode, because the use of the additional operation modes
requires additional knowledge about their functionality.
The additional modes available with Expert Mode set to 1 are "Power Boost", "Heater Protection" and
"Bypass".
Here again the modes in an overview:
Vaping with a constant power setting. The selected power is applied to the coil, unless
Mode0
the coil's resistance affords a different power setting or power is limited due to other
Power
reasons..
The power applied to the coil is calculated by a temperature controller which keeps the
Mode1
coil's temperature constant. Important to note: Set the correct temperature coefficient
Temp-Cont.
and perform a calibration at room temp.
Mode2
The power applied to the coil is repetively interrupted to enable a liquid flow und thus to
Heater-Prot.
limit the temperature.
The coil is quickly heated up initially. Moreover an repetitive boost can be selected.
Mode3
We recommend not to set the boost-power value too low but adjust a lower normal
Power-Boost
power setting to limit the coils temperature rise.
Mode4
The mod behaves like a mechanical mod, i.e. the battery voltage is directly applied to the coil.
Bypass
This, with the restriction, that the maximum current is 22A. Note that the vape now depends
on the charging level of the battery, and the coil should not be too low in resistance as then
22A is the limiting factor. If the resistance is too low in Bypass-mode, Err8 LowR is displayed
and vaping is not possible.
With "Set Defaults" it is possible to reset all settings to the delivery status.
The reset is initiated by selecting the menu an pressing a button. To avoid unintended
resetting the user has to confirm the procedure by again pressing the button when
"confirm" is displayed. "Process" shows that the rest is performed.
Most of the defaults are listed in the overview diagram of the Extended Functions Menu.
Those settings missing there are:
Power:
Temperature:
Heater Control Mode:
Wire Type:
can be used in 5 different modes. But in order to keep the menu
dicodes Dani Boxes
10W
210°C
0 (Power, normal VW)
NiFe (320)