Safety Instructions
1. Use the "Hook" to support the light fixture, not the electrical cord!
2. The light fixture is pre-wired at the factory to operate at 120 volts.
3. The light fixture is equipped with a multi-tap ballast for 120V, 208V, 240V and 277V applications. The leads
4. Never replace the Type-O lamp with the power supply "ON".
5. All work must be performed by a qualified Electrician.
6. This light fixture must be installed in accordance with the requirements of the National Electrical Code (NEC)
7. Use only Type-O specified replacement lamps.
Connecting the Light Fixture to a Power Supply other than 120 Volts
1. Remove the two screws (2) that hold the Access Cover to the light fixture. Disconnect and remove the
2. Route the incoming power cord (not supplied)
3. Remove the caps from the required leads and
4. Make all wiring connections.
5. Cap off all unused light fixture wires.
6. Re-attached the Access Cover to the enclosure.
7. Hang the light fixture as directed.
Hook Mounting and Cord Connection
1. This light fixture is supplied with a power cord plug pre-wired at the factory to operate at 120 volts.
2. Place self-locking hook over securely mounted eye hanger.
3. Proceed to Safety Cage installation instructions.
Safety Cage Installation
1. Place the light fixture on its side with the Access Cover
E n gi n e e red Pro d u cts Co m p a ny • 5401 Smetana Dri ve • Mi n n e to n ka, MN 55343 (800) 336-1976 • Fax (800) 336-2801
Caution: Recommended for use in "Low Bay" applications! Engineered Products
Company defines Low Bay applications as less than 25 feet off the floor.
Part Number: 15711 HID Light Fixture.
Part Number: 15757, HID 175 Watt MH Lamp, Type-O
!
Disconnect the Electrical Power at the Circuit Breaker Before Proceeding!
208V, 240V and 277V are capped off.
and must comply with all state and local electrical codes.
factory supplied power cord (see Figure 1). Cap
the unused supply cord hole.
through the knockout hole in the Access Cover
using a strain relief bushing or conduit fitting
(not supplied).
make sure to label the wires, then match the
voltage of the light fixture supply wires as
required.
Double check all wiring connections. Ensure that the proper light fixture voltage leads have been selected to match the
supply voltage. Improper wiring may damage the ballast and void the warranty.
CAUTION
!
Do not plug in the light fixture!
on top. See Figure 2. Locate the four (4) set screws
around the upper base of the lamp socket. Hold the
bottom of the Safety Cage (the larger end) and align
the "top" flat portion of the Safety Cage over the four set screws and rotate clockwise. Tighten each set
screw until the Safety Cage is firmly attached to the light fixture.
WARNING
Electrical Shock Hazard
Power Cord
Access Cover
Screws (2)
WARNING
!
.
Access Cover
.75" Knockouts
Figure 1. Reconfiguring the Power Supply.
Safety Cage -
Set Screws (4)
Figure 2. Installing the Safety Cage.
208V, 240V and
277V Ballast Leads
Flat portion
of Safety