Epever VS1024AU Manual del usuario

Navegue en línea o descargue pdf Manual del usuario para Inversor Epever VS1024AU. Epever VS1024AU 2 páginas. Au series

Epever VS1024AU Manual del usuario
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
※ Thank you for selecting ViewStar AU series solar charge
controller. Please read this manual carefully before using the
product.
ViewStar AU series solar charge controller
1. Overview
Thank you for selecting the ViewStar AU series common positive solar charge
controller. The VS-A controller is a PWM charge controller with built in LCD display that
adopts the most advanced digital technique. The multiple load control modes enable it can
be widely used on solar home system, traffic signal, solar street light, solar garden lamp,
etc. The features are listed below:
 Adopt high quality components of ST,IR and Infineon, make sure product using lifespan
 Terminals have UL and VDE certification, the product is more safer and more reliable
 Controller can work continuously at full load within the environment temperature range
from -25 to 55 ℃
 3-Stage intelligent PWM charging:Bulk, Boost/Equalize, Float
 Support 3 charging options: Sealed, Gel, and Flooded
 LCD display design, dynamically displaying device's operating data and working
condition
 Double USB design, the power supply charge for electronic equipment
 With humanized button settings, operation will be more comfortable and convenient
 Multiple load control modes
 Energy statistics function
 Battery temperature compensation function
 Extensive Electronic protection
2. Product Features
③ ④
Figure 1 Characteristic
LCD
MENU Button
RTS* Port
PV Terminals
※ USB output ports provide the power supply of 5VDC/2.4A and have the short
circuit protection.
Optional Accessory:
Name: Remote Temperature Sensor
Model: RTS300R47K3.81A
Acquisition of battery temperature
temperature compensation of control parameters, the
standard length of the cable is 3m (length can be
customized). The RTS300R47K3.81A connects to the port
③ on the controller.
NOTE: Unplug the RTS, the temperature of battery will be set to a fixed
value 25º C.
3. Wiring
Figure 2 Connection diagram
(1) Connect components to the charge controller in the sequence as shown above and pay
much attention to the "+" and "-". Please don't insert the fuse or turn on the breaker during
the installation. When disconnecting the system, the order will be reserved.
(2)After power on the controller, check the LCD on. Otherwise please refer to chapter
6.Always connect the battery first, in order to allow the controller to recognize the system
voltage.
Battery Terminals
Load Terminals
SET Button
USB Output Ports※
for
undertaking
1
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
(3)The battery fuse should be installed as close to battery as possible. The suggested
distance is within 150mm.
(4) The VS AU series is a positive ground controller. Any positive connection of solar, load
or battery can be earth grounded as required.
NOTE: Please connect the inverter or other load that it has the large start
current to the battery rather than to the controller, if the inverter or other
load is necessary.
4. Operation
4.1 Button Function
Button
MENU button
SET button
4.2 LCD Display
 Status Description
Item
PV array
Battery
Load
 Browse interface
NOTE:
1)
When no operation, the interface will be automatic cycle, but the follow two interfaces
not be display.
2) Accumulative power zero clearing: Under PV power interface, press SET button and
hold on 5s then the value blink, press SET button again to clear the value.
3) Setting temperature unit: Under battery temperature interface, press SET button and
hold on 5s to switch.
 Fault Indication
Status
Battery over
discharged
Battery over
voltage
Function
 Browse interface
 Setting parameter
 Load ON/OFF
 Clear error
 Enter into Set Mode
 Save data
Icon
Status
Day
Night
No charging
Charging
PV Voltage, Current ,Power
Battery capacity, In Charging
Battery voltage. current, temperature
Battery type
Load ON
Load OFF
Load Voltage, Current, Load mode
Icon
Description
Battery level shows empty, battery frame blink,
fault icon blink
Battery level shows full, battery frame blink, fault
icon blink
2