Axis A8004-VE Manual de instalación - Página 7

Navegue en línea o descargue pdf Manual de instalación para Cámara IP Axis A8004-VE. Axis A8004-VE 7 páginas. Configure the network video door station for the cybergate service
También para Axis A8004-VE: Manual de integración (6 páginas), Nota técnica (15 páginas)

Axis A8004-VE Manual de instalación
AXIS A8004-VE installation
Power 12V fail-secure lock by external power supply
NO/
NO/
-
-
CO
12V
CO
3V
NC
NC
IO1
IO2
12V
24V
REL
I/O
Configure relay state in AXIS A8004-VE
built-in web pages
1.
To check relay state, go to:
Setup > System Options > Ports & Devices > I/O ports
PoE+ Switch
2.
Depending on your lock type, con gure the following values
for RELAY, and click Save.
Open circuit for a fail-secure lock
Closed circuit for a fail-safe lock
I/O
Port Type
RELAY1
Relay
Max 30V,
Max 1.2A
V+
COM
NO
NC
REX
Name
Usage
Normal state is...
Door
Door
Open circuit
Open circuit
Closed circuit
Power
supply
Current Status
Open circuit