EPH COMBIPACK3 Manual de usuario sencillo - Página 2
Navegue en línea o descargue pdf Manual de usuario sencillo para Termostato EPH COMBIPACK3. EPH COMBIPACK3 5 páginas. Wireless non programmable thermostat
RF1 - Wireless Receiver
Contents
1.
Specifications & wiring
2.
Mounting
3.
Installation
4.
Button / LED description
5.
Resetting the RF1 receiver
6.
To connect the RF1 receiver to a RFRA
wireless thermostat
7.
To disconnect the RFRA thermostat from a
RF1 receiver
Important: Keep this document
Prior to operation, it is neccessary to complete all required settings described in this section.
1. Specifications & wiring
Power Supply: 230 Vac 50Hz
Contact Rating: 250 Vac 10(3)A
Ambient Temp: 0~50°C
Internal wiring diagram for RF1
* If mains voltage output is required,
terminals L & 2 must be electrically linked.
2. Mounting
The RF1 receiver should be wall mounted in an area within 20 metres
distance of the wireless thermostat.
It is important that the receiver is mounted more than 1 metre away from
metal objects as this will affect communication with the thermostat.
The receiver should also be installed at least 1metre from any electronic
devices such as radio, TV, microwave or wireless network adaptor.
The unit can be fitted to:
3. Installation
Slacken the fastening screw on the bottom of the receiver with a philips
screwdriver.
The receiver is hinged and can be opened 180 degrees. Mount the unit as
described in section 2. Wire the unit as described in section 1. Close the
receiver and tighten the fastening screw.
4. Button / symbol description
Connect button
Manual override
Class II appliance
Pollution degree 2: Resistance to
voltage surge 2500V; as per EN 60730
3
2
1
L
N
L
N
ON
COM
OFF
MAINS
SUPPLY
1. Recessed conduit boxes
2. Surface mounting boxes
System ON
(Green LED)
Reset button
Wireless connect
indicator (Red LED)
EPH Controls Ireland
[email protected] www.ephcontrols.com
Page 1 of 1
Operating Instructions
connections, you must first disconnect the device from
the mains. None of the 230V connections must be live
until the installation has been completed and the housing
is closed. Only qualified electricians or authorised service
staff are permitted to open the terminal box.
There are parts that carry mains voltage behind the cover.
The terminal box must not be left unsupervised when
open. (Prevent non specialists and especially children
from gaining access to it.)
Ensure that this wireless enabled receiver is installed 1
metre from any metalic object, television, radio or wireless
internet transmitter.
4. Button / LED description
Wireless connect: Once voltage has been applied this button may be
pressed to initialise the pairing process with the wireless thermostat. Once
pressed the red LED will begin to flash.
Manual override: This button will manually override the system.
Wireless connect indicator: This LED will flash on receiving wireless signals.
If it is constantly ON, the RF1 receiver has been disconnected from the
wireless thermostat.
5. Resetting the RF1 receiver
Press the
button located on the side of the receiver. Within 2 seconds,
RESET
press press the connect button. The RF1 receiver is now reset.
6. To connect the RF1 receiver to a RFRA
thermostat
The wireless connect LED will be constant red once power has been applied.
Press the
button on the RF1 receiver.
Connect
Both the red and green LED on the RF1 will begin to flash.
On the RFRA thermostat, press the
thermostat, the front housing will detach from the baseplate.
Press the CODE button on the printed circuit board.
When r1 appears on the screen, press the hand wheel once.
The thermostat is now connected to the RF1 receiver.
7. To disconnect the RFRA thermostat from a
RF1 receiver
On the RF1 receiver
Press the reset button on the right side of the housing.
Within 2 seconds, press the connect button.
The RF1 receiver is now disconnected from the RFRA thermostat.
On the RFRA thermostat
Press the
button on the bottom of the thermostat, the front housing
will detach from the baseplate.
Press the RESET button on the printed circuit board. "NO" will flash on the
screen.
Rotate the hand wheel clockwise until "YES" appears on the screen.
Press the hand wheel once to confirm the setting.
The thermostat is now disconnected to the receiver.
EPH Controls UK
[email protected] www.ephcontrols.co.uk
CAUTION!
Before commencing any work on the electrical
(Continued)
button on the bottom of the
20180826_RF1_OpIns_JW