DieHard 200.71226 Manual del usuario - Página 9

Navegue en línea o descargue pdf Manual del usuario para Cargador de batería DieHard 200.71226. DieHard 200.71226 16 páginas. Microprocessor controlled, fully automatic operation battery charger with engine starter plus battery and alternator tester

DieHard 200.71226 Manual del usuario
Ifthecharge m ode i schanged after c harg-
inghasstarted ( bypressing the CHARGE
RATE or CHARGE T YPEbutton), t he
charging process wilt b erestarted.
The voltage d isplayed during charging is
thecharging voltage a ndusually w illbe
higher than thebattery's resting v oltage.
71226 CONTROL
PANEL
DISPLAY MODE SWITCH
Use this switch button to set the function of
the digital display to one of the following.
• BATTERY %: The digital display shows
an estimate of the percent of charge of
the battery connected
to the charger
battery clamps.
• VOLTAGE: The digital disptayshows the
voltage at the charger battery clamps in
DC volts.
ALTERNATOR
%: The digital display
shows an estimated percentage of the
output of the vehicle charging system
connected to the charger battery clamps
as compared to a properly functioning
system.
CHARGE TYPE SWITCH
Use this switch button to set the type of
battery to be charged to one of the fol-
lowing.
• REGULAR:
This is the type of battery
usually used in cars, trucks, and motor-
cycles. These batteries have vent caps
and are often marked "tow maintenance"
or "maintenance-free".
• DEEP CYCLE:
Deep cycle batteries
are usually marked as "deep cycle" or
"marine". Deep cycle batteries are usu-
ally larger than the other types.
• AGM/GEL: AGM and get cell batteries
have sealed cases without vent caps.
Such batteries are often smaller than
the other types.
TOP OFF: Use the Top Off charge if your
battery is not fully charged, but close
enough to cause the charger to quickly
change to the Maintain mode after one
of the other charge types is started. Se-
lecting Top Off will cause the charger to
advance to the later stages of its charging
process then change to regular maintain
mode after charging is complete.
With the exception of AGM and get cell
batteries, all other battery types may or
may not have vent caps. Vent caps are
located on top of the battery and provide a
means to add distilled water when needed.
Batteries should be marked with their type.
If charging a battery that is not marked,
check the manual of the item that uses
the battery. If the battery type is unknown,
use the REGULAR setting. Make sure the
battery complies with the safety instruc-
tions on page 3.
CHARGE RATE SWITCH
Use this switch button to set the charge
rate to one of the following.
2ASLOWCHARGE
RATE: Intended for
charging small batteries such as those
commonly used in garden tractors, snow
mobiles and motorcycles. The 2A rate
is not intended to be used as a trickle
charger for larger batteries.
• 15A FAST or 40A RAPID
CHARGE
RATE:
Use for charging
automotive
batteries,
marine batteries, and deep
cycle batteries. Not intended for industrial
applications.
• 125A START: Provides 125 amps for
cranking an engine with a weak or run
down battery. Always use in combination
with a battery.
NOTE:
To turn OFF the charger, unplug
from the power cord from the wall outlet.