AMMETER:
The
ammeter indicates the measured amount of
amperes being drawn by the battery. When you first
start charging a battery, the reading will be high, with
the needle near 15 using the 15 amp charging rate.
In the MANUAL setting, as the battery charges, the
needle will fall to about 7 or 8 amps, indicating a
charged battery.
In either AUTOMATIC setting, the needle will fall to
zero and the charger will shut off when the
charger's control circuit senses a full charge. A
freshly charged battery's voltage will drop shortly
after charging, and the charger, if left connected,
may resume charging.
This off-and-on cycling will
continue until the battery's voltage no longer drops
enough to restart the charger.
At the 2 amp charging rate you will notice very little
needle movement.
When cranking the engine while using the ENGINE
START feature, the needle will swing into the Start (red)
area of the scale.
LED INDICATORS:
Two LED INDICATORS provide information on the state
of charge by glowing steadily or blinking at different
intervals.
GREEN,
FAST BLINK:
When the charger is charging a battery, the green LED
INDICATOR will blink rapidly approximately 4 times per
second.
GREEN,
STEADY:
In AUTOMATIC,
the green LED INDICATOR will glow
and the meter needle will be at zero, when the charger
has completed the charging cycle.
In MANUAL mode, YOU MUST monitor the charging
and stop the charging when the meter indicates about
half the selected rate, 2 or 15 amps. The charger has a
safety timer designed into the control, stopping the
charge upon reaching a maximum permitted time.
See chart to right.
GREEN,
SLOW BLINK:
The charger will be in the MAINTAIN mode when the
slow blinking green LED INDICATOR is operating. This
occurs only in the AUTOMATIC charging positions after
the end of the AUTOMATIC charging cycle, approxi-
mately 2 times per second.
RED, STEADY:
When the red LED INDICATOR glows steadily, it means
that the charger has not sensed a battery. The leads
may be reversed on the battery posts or one or both
connections may not be making a solid contact. Check
your connections.
DC AMPS
0
5
10
15
FULL
CHECK •
CHARGE
BATI'ERY
Rate,._,_ :,_M_mdm:Tlme,
2A
20 HRS.
15A
16 HRS.
RED, SLOW BLINK:
If, after a pre-set number of hours, the charger fails to
fully charge a battery, it will give up and the red LED
INDICATOR will blink slowly to tell you that something
is wrong with the battery, approximately 2 times per
second.
RED, FAST BLINK:
A rapid blinking red LED INDICATOR informs you that
the charger cannot operate with your control setting.
For example the controls are set on 12V.
AUTOMATIC REGULAR, and ENGINE START. The
ENGINE START feature will operate only in the
MANUAL mode--the red LED INDICATOR will blink
rapidly, approximately 4 times per second.
6