Diehl Metering HYDRUS Manual - Página 3

Navegue en línea o descargue pdf Manual para Mando a distancia Diehl Metering HYDRUS. Diehl Metering HYDRUS 4 páginas.

HYDRUS
Performance of volume test
Activate the test mode as described under General procedure.
After activating the meter display alternately indicates "Out 4" and the high-resolution
volume, e.g. 0.000000 m³ (Fig. D).
Fig. D
Meter display with activated test mode
HYDRUS now provides an output of the test pulse value for 3 hours shown in the display.
The value depends on the nominal size of the meter (Fig. E).
TEST PULSE VALUES:
Q3
TEST PULSE VALUES
1.6
2.5
4
6.3
10
16
25
Fig. E
Test pulse values
To end the test, briefly press button
control via the optical interface.
The yellow "ACT" LED on the device (see Fig. C) glows to indicate that the remote control is
in operation.
HYDRUS display no longer indicates "Out 4".
To prevent accidental discharge of the battery, always end the test by pressing button
Optical test pulses OFF)
(
HYDRUS.
Industriestraße 13
91522 Ansbach
Deutschland
Tel. +49 981 18 06-0
Fax. +49 981 18 06-615
www.diehl.com/metering
1 ml
2 ml
4 ml
4 ml
10 ml
40 ml
40 ml
(
and check that "Out 4" is no longer indicated on the display of
PULSE DURATION
OPTOHEAD
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
Optical test pulses OFF
) by holding the remote
page 3 of 4