Diehl Metering HYDRUS Manual - Página 3
Navegue en línea o descargue pdf Manual para Mando a distancia Diehl Metering HYDRUS. Diehl Metering HYDRUS 4 páginas.
HYDRUS
Performance of volume test
•
Activate the test mode as described under General procedure.
•
After activating the meter display alternately indicates "Out 4" and the high-resolution
volume, e.g. 0.000000 m³ (Fig. D).
Fig. D
Meter display with activated test mode
•
HYDRUS now provides an output of the test pulse value for 3 hours shown in the display.
The value depends on the nominal size of the meter (Fig. E).
TEST PULSE VALUES:
Q3
TEST PULSE VALUES
1.6
2.5
4
6.3
10
16
25
Fig. E
Test pulse values
•
To end the test, briefly press button
control via the optical interface.
•
The yellow "ACT" LED on the device (see Fig. C) glows to indicate that the remote control is
in operation.
•
HYDRUS display no longer indicates "Out 4".
•
To prevent accidental discharge of the battery, always end the test by pressing button
Optical test pulses OFF)
(
HYDRUS.
Industriestraße 13
91522 Ansbach
Deutschland
Tel. +49 981 18 06-0
Fax. +49 981 18 06-615
www.diehl.com/metering
1 ml
2 ml
4 ml
4 ml
10 ml
40 ml
40 ml
(
and check that "Out 4" is no longer indicated on the display of
PULSE DURATION
OPTOHEAD
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
0.1 ms/pulse
Optical test pulses OFF
) by holding the remote
page 3 of 4