Axium AX250i Manual de instalación y funcionamiento - Página 8
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Amplificador Axium AX250i. Axium AX250i 13 páginas. Two zone: two stereo pre-amplifiers & amplifiers with rs232, keypad & ir control
RCA
Zone 1 line outputs
Pre – out
Source select
2 way connector
Preset Utility
20 way Header
RCA
Expansion Bus
Audio Source
Line Level Inputs
Audio Source Inputs
CD, TAPE, TUNER, AUX & Utility are common to all zones.
The utility input is mono and connects to both left and right channels. Typical applications are
paging, or where a mono source is required (AM radio)
Line Outputs
SOURCE SELECT is the Zone 1 pre-fader output - independent of the volume control.
A typical application for this output is where speakers have volume pads installed and a slave
amplifier is required to operate the network at full power.
PRE-OUT is the Zone 1 post fader output
The output is muted when Zone 1 is muted
PRE-OUT may be used to drive a high power Slave amplifier or Active Sub-Woofer.
IR Out
A 3.5mm phono socket provides direct connection for IR emitters. The output is individually
buffered and current limited, this ensures that a damaged emitter does not short out the IR
system.
Expansion Bus
Axium amplifiers may be connected together via a 20 way IDC ribbon cable connection.
This simplifies the Audio source component connections. – CD, TAPE, TUNER, AUX & Utility are
connected to only one Axium amplifier!
The summed Amp-On output, Axium Bus, and buffered IR input are linked through the Bus.
Axium Bus is a 2 wire serial communication interface which provides inter-amplifier and controller
monitoring and control.
REAR PANEL CONNECTIONS
RCA
Mono Utility input
9 Pin connector
RS232
10 way connector
Controller connections
3.5mm phono
IR output
Speaker Outputs
Zone 2
Speaker D
Speaker C
IEC Fused
AC power socket
–
Output level is dependant on the volume control.
.
6
Zone 1
Speaker B
Speaker A