Olympus CK2-BIC Manual de instrucciones - Página 13

Navegue en línea o descargue pdf Manual de instrucciones para Microscopio Olympus CK2-BIC. Olympus CK2-BIC 15 páginas.

Olympus CK2-BIC Manual de instrucciones
Trouble
C.'M
Rem.:!)'
I)
Specimerl ii'T'la94! is partial·
Ob)tCtive is not fuliV engaged.
SlightlV rotate
OO$l:!p;eat
until
"
tv
OUt of fOCUli.
clicks into pl«:e. (p. 51
Speci"*, is not correctlV placed on
PIac:e
specimen oorrecttv. (p. 51
,_.
Opticill per-Iormance of $p8Cimen
Mow lPflCimen vessel 00 find PIO·
.....
(e.lI. flatness 01 bottoml
"
per position or repi«:e, (p.61
IOsulficient.
III Specimen image partlillllv
Lillht source is not correctly
Center light source correctly (p,41
blurred.
Centered.
2. Electric system
.,
Light Ilickers and intensitV
Line voltage is unstable.
Use a voltage stabilizer.
is unstable.
Filament of bulb is likelv to burn
Replace defective bulb. (p 41
O<H.
Loose electric connection.
Tighten connection.
b) Fuse burns out too often,
Fuse is not a standard one.
Use a standard luse. 12nd cover I
Bulb is not a stanclard ooe
Use 5V 'lOW halOlJen bulb as de·
s;gf\ilted (2nd coverl
cl Pilot lamp lights but illu·
Bulb is burned OUI.
Replace delective bulb.
minator bulb
does
not.
No bulb
;,
connected
<0
bulb
Connect bulb to socket
""'M
Cords or plugs are
not oomected
Connect them completely.
3. FocuslfIlI
.1 Co¥se adjustment knob is
Focus adjustment kn0b5 are t91t·
Loosen adjustment kllObs.
tOO tight.
ened
tOO much.
bl Specimen goes out 01
FoctJt adjustment knobs are loosen·
Tighten adjustment knobs
-,.
ed tOO much.
4. ObserYltion tube
.1 Incomplete binocular
lnterpupillar-v dIstance IS not
COf·
Adjust intet'PllpiliarV distance.
VISIon
rectlvadjUSted
(p. 51
Diopter adjustment is incomplete
Complete diopter adjustme1lt,
(p.5)
User is unaccustomed to binocular
Prior
"
looking at specimen de·
vision.
l3ils, try to look at entire field 01
view. or look ilt a far
lrNav
oblect
before resuming microscopic
.,.
servation. (p_ 5)
5. PtlotomicrOWaphv
ill)
Picture
is
Out of fOOJs,
Shulter
.,...
of
OM
~.
;,
Prolong shutter
speed
bV means of
faster than
In
second
NO lilters. elC. (p.61
-
-
bl Picture vignettes.
Achromatic objective is used,
Use Plan objective, (p. 71
d
Focus
it
nOt sharp.
Correction collar of 4QX objecti\oe
Adjust correction coll.r ICCOl"d,nu
is not adjusted
to thickness of
vessel
bottom.
(p.51
dl Room window or lluores·
ex.\filfleou$ light enters eyepieces or
Cap
eyep.eoes or telescooe, (p 81
cent I.lmp isphotOlJr,lphed.
locuslrllJ telescope.
III
"
• g
r
m
'i'
g
"
z
" "
c
o
m