Olympus MX61A Manual - Página 4

Navegue en línea o descargue pdf Manual para Equipos de laboratorio Olympus MX61A. Olympus MX61A 48 páginas. Motorized 300 mm compatible semiconductor/fpd inspection microscope

IMPORTANT
This microscope employs a UIS2 (UIS) (Universal Infinity System) optical design, and should be used
only with eyepieces, objectives, observation tubes, etc. specified for use with the UIS2 (UIS) optics.
Less-than-optimal performance may result if inappropriate accessories are used.
The MX61A microscope is compatible with stage strokes of 200 mm (8 inches) and 300 mm (12
inches). Its control can be motorized by using the MX-OPU61A Operation Unit (with built-in computer)
and a PC in which the MX2-BSW Control Software is installed. The motorized control is also available
using the MX-HS61A Hand Switch with the jog dial control capability (the MX-OPU61A or the MX2-BSW
software should also be used in combination with the MX-HS61A Hand Switch).
SAFETY PRECAUTIONS
1. Always use the power cord provided by Olympus. If no power cord is provided, please select the power cord by referring
to the section "PROPER SELECTION OF THE POWER SUPPLY CORD" at the end of this instruction manual. If the proper
power cord is not used, Olympus can no longer warrant the electrical safety performance of the equipment. Lay out the
power cord at a sufficient distance from the sources of heat such as the power supply unit/light source and lamp housing
to avoid contact with these heat sources.
2. To avoid potential shock hazard, always set the main switch of the BX-UCB control box to "
power cord before replacing the bulb/burner or connecting/disconnecting motorized parts. And since the system contains
motorized parts, do not plug in the power cord until all of the assembly procedures have completed.
}Always use the lamp bulb or burner supplied by Olympus.
Halogen bulb
Mercury burner
Xenon burner
Halogen bulb for light guide
light source
3. Do not light the mercury or xenon burner while it is not mounted on the microscope because the UV rays in their light are
harmful to your eyes.
The used mercury burner should be disposed of as an industrial waste.
4. The eye point of this microscope can be adjusted in the range between 408 and 560 mm above the desktop surface (with
basic combination). According to the SEMI standard guidelines (SEMI S8-0705), prepare a microscope desk with an
optimum height for the application of the customer.
1
Bulb/Burner
· 12V100WHAL-L (Long life type)
(PHILIPS 7724)
· 12V100WHAL (High-resolution type)
(PHILIPS 7023)
· USH-103OL
(USHIO)
· HBO103W/2
(OSRAM)
· UXL-75XB-A
(USHIO)
· JCR12V-100WB
(USHIO)
Model
" (OFF) and disconnect the
Average Life
2000 hrs.
50 hrs.
300 hrs.
300 hrs.
200 hrs.
1000 hrs.