Axon Synapse HDR07 Manual técnico - Página 14

Navegue en línea o descargue pdf Manual técnico para Amplificador Axon Synapse HDR07. Axon Synapse HDR07 18 páginas. Re-clocking hdsdi distribution amplifiers

The Message String
The Tag
Defining Tags
Event Menu Item
Tag
Announcements
0 or NA
Signal_Input
01
PLL_State
02
The Priority
The Address
The message string is defined in the card and is therefore fixed. It
may be used in controlling software like Cortex to show the
event.
The tag is also defined in the card. The tag has a fixed meaning.
When controlling or monitoring software should make decisions
based on events, it is easier to use the tag instead of interpreting a
string. The first implementation is the tag controlled switch in the
GPI16.
In cases where the event marks a change to fault status (e.g. 1 for
Loss of Input) the complement is marked by the tag increased by
128 (80
) (e.g. 129 (81
hex
The tags defined for the HDR07 are:
=INP_LOOSED
hex
=PLL_LOCKED
hex
The priority is a user-defined value. The higher the priority of the
alarm, the higher this value. Setting the priority to Zero disables
the announcement of this alarm. Alarms with priorities equal or
higher than the Error Threshold setting of the RRC will cause the
error LED on the Synapse rack front panel to light.
Together with the message string or the tag, the slot number or
address of the card is relevant to be able to assign the event to a
certain card.
) for Return of Input).
hex
0 or NA
81
=INP_RETURN
hex
82
=PLL_UNLOCKED PLL lock or unlock
hex
12
Description
Announcing of
report and control
values
SDI input loosed or
returned