COAXIAL SURGE PROTECT
The PowerLight 2400 includes convenient "F" style
connectors for hooking up satellite and cable TV. This
allows full surge protection to these often overlooked
sources of possible lightning spikes. This is a low loss
pass-through connection.
Simply connect the coaxial cable coming from the wall
(or satellite dish) to the corresponding connector
marked "IN." Connect an additional cord from "COAX
OUT" directly to the desired VCR, TV, or DSS Tuner.

LIGHTNING AND SURGE PROTECTION

The PowerLight 2400 will help protect all equipment
plugged into its outlets from lightning strikes and power
line surges. If the lightning strikes a distant power line,
the PowerLight 2400 will protect your equipment
invisibly and harmlessly.
In the unlikely event that lightning strikes your actual
building or a location close to it, the PowerLight 2400
will protect your equipment, but may sustain some
minor damage to its internal fuses and MOV's. This
will be indicated if the front panel PROTECT indicator
is not on. If this is not lit, have the unit inspected at a
local repair shop, or return it to the factory for
inspection and recalibration. There is a nominal charge
for refitting and recalibrating the PowerLight 2400.
In extremely active lightning areas, we recommend the
extra precaution of a whole house lightning protector,
installed at the incoming breaker box for maximum
protection. Contact your local utility company or a
licensed electrician for more details.

CARE AND MAINTENANCE

The PowerLight 2400 is manufactured from the finest
components. It will provide many years of flawless
performance with little or no maintenance, aside from
occasionally wiping the front panel with a mild glass
cleaner. Do not use harsh solvents as they may harm
the finish. Please do not open the sealed cabinet. There
are no user serviceable parts inside.
Thank you for choosing Cinepro.
Enjoy your new component.

Specifications:

Current rating:
Input voltage:
Active Voltage Protect:
Meter accuracy:
Remote trigger voltage:
Spike protect modes:
Clamping voltage:
Response time:
Max surge current:
Max spike energy:
Noise attenuation:
RF pass thru loss:
Dimensions:
Construction:
Power consumption:
Fuses:
Safety information:
Filter noise attenuation-RFI
(loss measured into a 50 ohm system)
Approvals:
20 amps, fuse protected
75-140 VAC
Below 90 or above 136 VAC
±3 VAC
12 volts AC/DC
Line to neutral, neutral to ground,
line to ground
250v peak (175 Volts RMS.)
1 nanosecond
58,500 amps
2880 joules
>25 dB @ 200 kHz
>60 dB @ 5 MHz
Less than 1 dB (below 800 MHz)
1.75x19x8" (H<W<D), 12 Lb.
UL approved components
Mil spec glass epoxy circuit boards
Steel chassis, zinc chromate plating
Twin aluminum slide out lamp tube
on Teflon bearings.
Control circuits – 12 watts
Main – 15 Amps, 120/250V
Sense– 250 ma., 120/250 V
UL, CSA, and Canadian UL app.