S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
Children as well as adults with physical, mental and/or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The product may only be used for bathing, hygienic and body cleaning purposes.
The product may not be used as a holding handle. A separate handle must be
installed.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 05)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
M A I N T E N A N C E (see page 05)
The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
Hot and cold supplies are reversed (see page 08)
D I M E N S I O N S (see page 06)
F L O W D I A G R A M (see page 06)
 Hand shower
 Bath Spout
S P A R E P A R T S (see page 07)
S P E C I A L A C C E S S O R I E S (order as an extra)
F A U L T
⁄ Insufficient water
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Spout temperature does not correspond with temperature
set
⁄ Instantaneous heater didn't work
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
C A U S E
⁄ Shower filter seal dirty
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ Hot and cold supplies are reversed
⁄ Shower filter seal dirty
⁄ Flow limiter in handshower isn't removed
extension 60 mm #93882000 (see page 07)
C L E A N I N G (see page 10)
O P E R A T I O N (see page 09)
R E M E D Y
⁄ Clean filter seal between shower and hose
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Install function block turned through 180º (see page 08)
⁄ Clean filter seal between shower and hose
⁄ Remove flow limiter