Axor Citterio Select 230 2jet 39867 9 Series Instrucciones de uso/montaje - Página 2

Navegue en línea o descargue pdf Instrucciones de uso/montaje para Sanitarios Axor Citterio Select 230 2jet 39867 9 Series. Axor Citterio Select 230 2jet 39867 9 Series 12 páginas.

EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
⁄ The mixer can not used together with a continuous flow water heater.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 09)
M A I N T E N A N C E (see page 10)
The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
D I M E N S I O N S (see page 08)
F L O W D I A G R A M (see page 08)
S P A R E P A R T S (see page 11)
XX = Colors
00 = Chrome Plated
80 = Stainless Steel Optic
S P E C I A L A C C E S S O R I E S (order as an extra)
extension #43333000 (see page 09 / 11)
C L E A N I N G (see page 07)
F A U L T
⁄ Insufficient water
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping at the threaded base
⁄ Hot water temperature too low
⁄ Select button stiff
A S S E M B L Y (see page 05)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
C A U S E
⁄ Aerator calcified, dirty
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ connection hoses not completely screwed into basic body
⁄ O-ring at the connection hose defective.
⁄ Hot water limiter incorrectly set
⁄ Select button soiled
O P E R A T I O N (see page 10)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Minor leaking may occur briefly at the spout when opening the fitting via
the lever.
⁄ Use the lever to open the tap and set the desired temperature. The water
flow can be paused by pressing the Select button on the face side of the
spout. When the tap is not used for a longer period of time, f.e. when
retiring at night or leaving the house, it must be closed completely by
means of the lever.
R E M E D Y
⁄ Clean aerator, replace as necessary
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter
⁄ Clean Select button and grease (14x1,5) O-ring
(see page )