AccuraSEE MINT Manual del usuario - Página 4
Navegue en línea o descargue pdf Manual del usuario para Ventilador AccuraSEE MINT. AccuraSEE MINT 5 páginas. Portable heat recovery ventilator
Figure 3. Installation of the product using a ventilation kit.
RECOMMENDATIONS
Screens (not bundled with the product) shall be attached to the ports of the ventilation kit
to prevent the encroachment of animals that can damage the product or constitute hazard
to the building occupants.
A minimum separation distance of 1 ft is recommended between the supply and exhaust
ducts.
The ducts (B and D) shall be installed without any bends that may impede the flow of air.
The ducts (B and D) shall be insulated to minimize energy losses.
Maintenance
A few activities may be performed during the course of using the product.
NOTE
The heat exchanger (H)
The product shall be shut down before any maintenance activity is performed.
shall not be washed.
Filter
It is recommended to change the filter in the supply vent (A) at least once in three
NOTE
months depending on the outdoor air quality. The procedure for changing the filter is
A filter shall not be
presented as follows.
installed in the exhaust
vent (C).
To remove the old filter in the supply vent (A):
o Shut down the product;
o Open the door of the enclosure;
o Locate and hold the heat exchanger (H) firmly with one hand;
o Carefully twist and pull out the supply vent (A) with the other
hand.
5
Remove the filter in the supply-vent (A) port and replace it with a new
NOTE
filter.
Excessive force shall not
be applied when
To reinsert the supply vent (A):
replacing the filter in the
o Clean the vent (A) with a paper towel that is moistened with
supply vent (A).
isopropyl alcohol;
o Use one hand to hold the heat exchanger (H) and ensure that it
lines up with the port of the supply vent (A) at the top of the
enclosure;
o Use the other hand to insert the supply vent (A) into the port until
it is flush with the top surface of the enclosure.
Duct
A damaged duct can be replaced by using a similar duct with a diameter of 4 in
NOTE
(~10.2 cm).
The length of a newly
installed duct shall be
The following steps can be followed when changing a duct:
5 in (~12.7 cm).
o Shut down the product;
o Loosen the nuts of the clamp of the damaged duct;
NOTE
o Remove the damaged duct from the port of the appropriate fan;
Do not apply excessive
force when tightening
o Attach a new duct to the port of the appropriate fan;
the clamp.
o Tighten the nuts of the clamp.
Electrical Parts
An electrical part (F, G, I, and J) shall only be replaced if it is faulty. In this situation,
the product shall be shut down and the manufacturer shall be consulted for further
instructions.
†
Caveat
The electrical parts (F, G, I, and J) of the product are deemed to be certified to ensure
customer safety. Products are submitted for field inspection only if a request is made to
the manufacturer. Consequently, the manufacturer is not liable if approval is required
by the Authority Having Jurisdiction where the product is purchased and/or installed.
6