ARCA LS100 Manual del usuario - Página 20
Navegue en línea o descargue pdf Manual del usuario para Escáner ARCA LS100. ARCA LS100 20 páginas.
General features
Environmental conditions:
Temperature:
Humidity (without condensation):
Electromagnetic immunity:
The product will function correctly if positioned at an adeguate distance distance of an
electromagnetic emission source (video, PC, etc..)
Power supply:
Machine:
External power supply:
The power supply is switching on and it is supplied with the power cord of the right type
depending on the destination country.
Product size:
Width:
Depth:
Max. Height:
Weight:
Machine:
Power supply:
Document features:
Height:
Length:
Thickness:
Weight:
Image features:
Resolution:
Grey scale:
Illumination:
Software tools
Specific LS100 API interface, LSfamily scanners common API and API test program LS100 test
program which also includes calibration procedures.
All software tools and API work in:
Operator Manual
20
LS100
from 10°C to 40°C (50 to 104 °F)
from 20% to 80%
- In: 24 V dc
- In: from 100 to 240 V 50/60 Hz
215 mm (8,47 in)
125 mm (4,92 in)
160 mm (6,30 in)
2 Kg (4,4 lb) for maximum configuration
0,3 Kg (0,661 lb)
from 50mm (1,97 in) to 105mm (4,3 in)
from 100mm (3,94 in) to 216 mm (8,50 in)
from 0.07mm (0,003 in) to 0.10mm (0,004 in)
from 70 g/mq (0,01 lb/sqf) to 110 g/mq (0,02 lb/sqf)
(100 dpi x 100 dpi) (3.93 X 3.93 ppmm)
(200 dpi x 200 dpi) (7.87 X 7.87 ppmm)
256 or 16 grey levels
RGB illumination
Windows XP / W2K / VISTA / 7 / 8 / 10 (x32 and x64 bit)
Linux
TWAIN driver available
- Out: 24 V dc
- Power: 36 Watts