CIPU CSPPD705 Manual - Página 7

Navegue en línea o descargue pdf Manual para Bomba de piscina CIPU CSPPD705. CIPU CSPPD705 13 páginas.

CIPU CSPPD705 Manual
In climates where the pump may be exposed to frost or freezing, care must be taken to ensure
the pump is protected from damage. It is recommended that if the pump is not used during
winter period it should be drained completely and store pump in a dry location. Do not replace
the drain plug. Store it in a safe place when not use. An example would be store plug in the
filter tank basket.
When you are activate the pump ensure all seals and o-rings are in operational condition,
re-grease if necessary, replace if unsure of condition.
Check that the motor shaft moves freely before re-activation.
1. When connecting electric cables to the motor of the pump, be careful to correctly arrange
them inside the connection box, verify that no bits of cable are left inside the box on closing it.
See that the ground wire is correctly connected. When connecting the motor, follow the wiring
diagram supplied with the pump.
2. Be especially careful that no water enters the motor or electrical parts under voltage.
3. In the event that the planned use is not as specified, adaptations and supplementary
technical rules may be necessary.
4. Before starting the pump, verify the calibration of the electrical protection devices of the
motor and that the protections against electrical and mechanical contacts are correctly
positioned and attached.
5. It is advisable to follow the steps listed below before handling the pump in any way.
a) Turn off the voltage to the pump.
b) Lock starting devices.
c) Verify that there is no voltage in the circuits, including ancillary devices and auxiliary circuits.
d) Wait until motor stops completely.
The above list should be considered indicative and not binding for the purpose of safety,
specific safety rules may exist in particular regulations.
Assembly Instructions (some parts may be pre-assembled)
Follow the step below and the corresponding diagrams for assembly.
Step 1.
Place the strainer basket to the strainer housing. Be sure that the opening the basket is
aligned with the opening in the housing. Secure Lid
Step 2.
The water level of the inground swimming pool is lower than the water inlet of the pump.
In order to prevent water from flowing backward, this pump equipped a check valve.
First screw the adapter into the water inlet of the pump, and then install the connector
assembly.
6