CIPU CSPPS702 Manual del usuario - Página 9

Navegue en línea o descargue pdf Manual del usuario para Bomba de piscina CIPU CSPPS702. CIPU CSPPS702 11 páginas.

CIPU CSPPS702 Manual del usuario

TROUBLESHOOTING

Problem
Cause
Low flow
Dirty filter
Dirty skimmer and
pump strainer
Suction air leak
Closed valve or
blocked line
Pump does
Not plugged in
not run
GFCI/or main circuit
breaker tripped
Faulty Pump shaft
/motor
Pump shaft is locked
Pump will
Suction air leak
not prime
No water in the pump
Closed valves or
blocked lines
Motor
Motor not connected
overload
properly
cuts out
Low incoming voltage
Overload due to
binding in pump or
wrong size impeller
Solution
Backwash or clean cartridge
Clean skimmer and pump strainer
Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
Check the socket and power cord
Switch on the breaker. If it is immediately
tripped again,
There is a defect in pump or controls.
Replace the pump/motor assembly.
Check if the pump can be rotated by hand and
remove any blockage
Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
Make sure the filter tank is full
Open all valves in the system, clean skimmer
and pump basket, check pump impeller of
blockage
Have electrician check wiring
Voltage at motors should be no more than 6%
above or below nameplate voltage. Have
electrician check voltage; ensure pump is not
running on an extension cord. Report low
supplier to authorities.
Contact supplier
8