INSTALLATION INSTRUCTIONS
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
WIREWAY
3.5
O
(2)
7/16"
CLEARANCE
MOUNTING PATTERN
(ORIENTATION)
FIXTURE
FRONT OF
FIXTURE
CAPTIVE
SCREWS
DOME DETAIL
INSTALLATION STEPS:
1. TURN OFF POWER.
2.
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
3.
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST;
ASSEMBLE FIXTURE TO ARM WITH (2) CAPTIVE SCREWS
(AS SHOWN), CLOSE BALLAST COMPARTMENT.
4.
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
COMMON, BLACK TO HOT AND GREEN TO GROUND).
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
INCOMING EQUIPMENT GROUND SUPPLY.
5.
PLACE WIRING IN POLE AND SECURE FIXTURE
TO POLE (HARDWARE AS NOTED).
6.
INSTALLATION COMPLETE.
14249 Artesia Blvd. P.O. Box 1869
(714)994-2700 fax(714)994-0522
MOUNTING HARDWARE
FOR POLE BY AAL,
HARDWARE INCLUDED.
FOR POLE BY OTHERS,
10.00
HARDWARE BY OTHERS.
CONNECTORS
CAPTIVE SCREWS
DOME
LAMP (REFERENCE)
(BY OTHERS)
1
8-32 X 1/4"
PHMS S/S
(2) P/N A84031
La Mirada, CA 90638-1869
INCOMING
WIRE
WIRE LEADS
CONNECTIONS
(BY OTHERS)
2
ARM
CONNECTORS
LATCH
BALLAST
1
FITTER CAP
TABS
BALLAST SERVICING:
1.
TURN POWER OFF.
2.
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST.
3.
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
TO RELEASE BALLAST,
4.
SERVICE BALLAST.
5.
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
AND SECURE WITH (2) SCREWS. CLOSE FIXTURE
LATCH SECURELY.
6.
BALLAST SERVICING COMPLETE.
LAMP SERVICING:
1. TURN POWER OFF.
2.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
3. LIFT FITTER CAP FROM FITTER.
4.
INSTALL LAMP (BY OTHERS).
5.
CAREFULLY PLACE FITTER CAP ASSEMBLY INTO
FITTER, ROTATE FITTER CAP CLOCKWISE UNTIL TABS
SNAP SECURELY INTO FITTER.
6.
LAMP SERVICING COMPLETE.
3/8-16 X 1" LG
SHCS S/S
(2) P/N A84186
CLOSED
FITTER CAP DETAIL
2
DATE
APPRVD
DATE
REV.
CATALOG NUMBER
PROS IND
TRA59D
4" O.D. POLE
(REFERENCE)
OPEN
PART NO.