Digiflex SMART RF RF120 Manual de referencia del instalador - Página 3

Navegue en línea o descargue pdf Manual de referencia del instalador para Transceptor Digiflex SMART RF RF120. Digiflex SMART RF RF120 8 páginas. Base station with relay outputs

ers as required in strategic locations. Up to 4 receiv-
ers can be added.
Installation
The receiver should be installed onto a solid surface
using suitable mounting fixtures. Wiring should only be
performed while the control panel is powered down.
Step 1) Unlock and remove the front of the housing by
turning the cam lock anti-clockwise [Figure 4]
then release the spring clips and remove the
PCB, This will expose the mounting and tamper
screw holes.
Step 2) Mark out the location of the mounting holes
and the cable exit hole before drilling out all
Figure 4: Cam Lock Shown
In The Unlock Position
Copyright © 2021
CAUTION - Figure 3 below is a guide only and is not a 1:1
mounting template for the RF120/RF121. Do not scale.
Figure 3: Mounting Holes, Cable Knock
Out's & Rear Tamper Locations
E&OE
points as necessary. Secure the case using fix-
tures appropriate for the wall construction type.
Make sure to fit the rear tamper screw when
mounting as shown.
Step 3) Feed any wires into the case via the knockouts
provided and then replace the PCB by inserting
from the terminal side first and then clipping
the other side in.
Step 4) Set the address for the module and connect
and necessary wiring. Unused wires should be
insulated to prevent short circuits.
Step 5) Once all connections are secure and the case is
mounted, secure the front case and lock in place
by turning the cam lock in a clockwise direction.
Rear
Tamper
Mounting
Holes
Cable
Knock Outs
Cable
Knock Outs
Figure 5: Rear Tamper Screw
P/N: RF120-RF121IRG Rev 1.30
Page
3