Cres Cor H138NPS1813CLA Instrucciones de uso y mantenimiento - Página 3

Navegue en línea o descargue pdf Instrucciones de uso y mantenimiento para Equipamiento alimentario comercial Cres Cor H138NPS1813CLA. Cres Cor H138NPS1813CLA 5 páginas. Pass-thru hot cabinet series

5925 Heisley Road • Mentor, OH 44060-1833
877/CRES COR (273-7267) • 440/350-1100
Fax: 440/350-7267 • www.crescor.com
OPERATING and MAINTENANCE INSTRUCTIONS
Model H138NPS1813CLA and H138NPS1832CLA
BEFORE CLEANING THE CABINET:
1. Allow cabinet to cool.
2. Do NOT use abrasives or harsh chemicals.
HOW TO CLEAN UNIT:
SOIL
DIRT
FINGERPRINTS, GREASE
and OIL
WATER SPOTS
*Mild detergents include soaps and non-abrasive cleaners.
TROUBLE SHOOTING CHART:
FAILURE:
1. Yellow light on switch does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won't shut off.
4. Blower does not work or makes noise.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Pass-thru Hot Cabinet Series
CLEANER
Mild detergent* and hot
water, or mild abrasive
cleaner.
Steam (no strong alkaline
additive).
Chemical oven cleaner.
Mild abrasive cleaner; oily
or waxy cleaner.
Mild abrasive cleaner.
Pass-thru
Holding Cabinet
Rev. 3 (9/04)
Cleaning Notes:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt
build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer's directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
METHOD
1. Use soft, damp cloth.
2. Rinse with hot water
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven cleaner
manufacturer's directions
Apply with a soft, clean cloth.
1. Apply with damp cloth.
2. Rinse and dry.
POSSIBLE CAUSE:
1a. Circuit breaker/fuse to wall outlet is blown
1b. Cord is unplugged from wall outlet.
1c. Switch is "OFF."
2a. Thermostat set too low or is "OFF."
2b. Switch is "OFF."
3a. Defective electrical parts. UNPLUG UNIT
FROM WALL OUTLET:
4a. Defective blower
FL-2254LA
3 of 5
Page