Cres Cor CO151F1818B-Q1 Manual de instalación, uso y mantenimiento - Página 7

Navegue en línea o descargue pdf Manual de instalación, uso y mantenimiento para Horno de convección Cres Cor CO151F1818B-Q1. Cres Cor CO151F1818B-Q1 13 páginas. Convection and retherm ovens with microprocessor controls
También para Cres Cor CO151F1818B-Q1: Manual de instalación, uso y mantenimiento (13 páginas)

5925 Heisley Road • Mentor, OH 44060-1833
PROBLEM
Cabinet does not heat, or doesn't heat
properly
Blowers do not operate
Heater will not shut off
Vent fans do not shut off
Vent fans do not operate (See Note)
Control will not switch from "COOK" to
"HOLD" (timed mode)
Control will not switch from "COOK" to
"HOLD" (probe mode)
Control will not switch to "COOK" (probe
mode)
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualifi ed electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers.
Instructions for replacing parts are included in replacement parts list.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE (continued)
POSSIBLE CAUSE
1.
Fuse
2.
Control
3.
Sensor
4.
Heater contactor
5.
Loose wiring at heater contactor
6.
On/Off Switch
1.
On/Off Switch
2.
Fuse
3.
Blower
4.
Control
1.
Control defective
1.
Vent fan switch defective
2.
Control compartment is still hot.
1.
Fuse
2.
Vent fan switch defective
3.
Vent fan defective
1.
Oven is in "PROBE" mode.
2.
Control defective
1.
Oven is in the "TIMED" mode
2.
Probe not plugged in
3.
Control defective
1.
Oven in "TIMED" mode
2.
Probe temperature setting lower than
probe temperature
3.
Probe not plugged in
4.
Control defective
Ovens with
Microprocessor Controls
Rev. 10 (6/08)
SOLUTION
1.
Replace
2.
Replace
3.
Replace
4.
Replace
5.
Replace
6.
Replace
1.
Replace
2.
Replace
3.
Replace
4.
Replace
1.
Replace
1.
Replace
2.
Wait until it cools
Check "Heater will not shut off"
1.
Replace
2.
Replace
3.
Replace
1.
Switch to "TIMED" mode
2.
Replace
1.
Switch to "PROBE" mode
2.
Plug in probe
3.
Replace
1.
Switch to "PROBE" mode
2.
Set probe temperature to
desired temperature
3.
Plug in probe
4.
Replace
FL-2269
Page 7 of 13