Cres Cor RO151FUA18 Manual de instalación, uso y mantenimiento - Página 7

Navegue en línea o descargue pdf Manual de instalación, uso y mantenimiento para Horno de convección Cres Cor RO151FUA18. Cres Cor RO151FUA18 10 páginas. Cres cor inc. convection and retherm ovens installation, operation and maintenance manual

5925 Heisley Road • Mentor, OH 44060-1833
PROBLEM
Cabinet does not heat, or doesn't heat
properly
Blowers do not operate
Heaters will not shut off
Vent fan does not shut off
Vent fans do not operate (See Note)
Control will not switch from "Cook" to
"Hold" (timed mode)
Control will not switch from "Cook" to
"Hold" (probe mode)
Control will not switch to "Cook" (probe
mode)
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualifi ed electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers.
Instructions for replacing parts are included in replacement parts list.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE, continued
POSSIBLE CAUSE
1.
Fuse
2.
Control
3.
Sensor
4.
Heater contactor
5.
Loose wiring at heater contactor
6.
On/Off Switch
1.
On/Off Switch
2.
Fuse
3.
Blower
4.
Control
1.
Control defective
1.
Vent fan timer defective
2.
Vent fan timer has not timed out
1.
Fuse
2.
Vent fan timer defective
3.
Vent fan defective
1.
Oven is in probe mode
2.
Control defective
1.
Oven in timer mode.
2.
Probe not pluged in.
3.
Control defective.
1.
Oven in timer mode.
2.
Probe temperature setting lower than
probe temperature
3.
Probe not plugged in
4.
Control defective.
FL-2202-MP-M
Ovens
Rev. 1 (4/08)
Page 7 of 10
SOLUTION
1.
Replace
2.
Replace
3.
Replace
4.
Replace
5.
Replace
6.
Replace
1.
Replace
2.
Replace
3.
Replace
4.
Replace
1.
Replace
1.
Replace
2.
Wait until timer has timed out
(about 45 minutes after power
switch is turned off)
1.
Replace
2.
Replace
3.
Replace
1.
Switch to timer mode
2.
Replace
1.
Switch to probe mode.
2.
Plug in probe.
3.
Replace
1.
Switch to probe mode.
2.
Set probe temperature to desired
temperature
3.
Plug in probe
4.
Replace