Visualizing in meters or feet
Setting 0 measures are expressed in meters, setting 1 in feet. Range allowed 0 or 1.
N.B.: the conversion in feet is possible only during the working phase, during the programming
the measure unit is always in metric.
Example:
Use of display
At any irrigation, before unwinding of tube, is necessary zero set the instrument pressing for about 6
seconds RESET until appears zero on the display; this way the display is initialized and ready for a new
irrigation.
N.B.: this operation is necessary to have the correct values of unwound tube and of end irrigation time.
Now can start with the drawing of tube: do not exceed the maximum speed of trolley load
recommended by the manufacturer of the irrigator. In this phase the instrument shows on the display
the meters of unwound tube and keys METER and TIME are switched off.
When the irrigation starts (re-entry) the display recognizes the direction change and shows on the
display the irrigation speed in meters/hours (or feet/hours, it depends on what was programmed in
constant CA) .
Pressing key METER on the display appears the meters of unwound tube (or feet), visible until keeping
the key pressed, leaving the key returns the irrigation speed.
Pressing on TIME appears the remaining time of end irrigation in hours and minutes that is visible until
keeping the key pressed, leaving the key returns the irrigation speed.
If for about 2 seconds do not arrive impulses from the transducer, the instrument switches off
automatically keeping in memory the unwound meters. When the impulses return the instrument
switches on automatically and restart to count from where it stops.
During the irrigation phase or drawing of tube its recommended to not keep pressed key RESET longer
then 3 seconds or the instrument will zero set and loose all the dates of speed, unwound meters and
remaining time until those moment and the values visualized on the display will be completely wrong.
Display features
•
Speed visualizing
•
Tube length visualizing
•
Visualization of remaining irrigation time
•
Allowed speed rotation
•
Power supply
•
Battery length
•
Working temperature
•
Shock-proof, self extinguishing case
•
Case protection degree (frontal)
•
Bores
•
Electromagnetic compatibility
Transducer features
•
Dimensions
•
Connection cables
•
Working temperature
•
Protection degree
Data: 20/02/06
5
4
3
2
1
2
3
4
5
Ø1500
File : VIR_SP_ing.doc
C2=1500
C3= 5
C4= 9
6
7
8
9
C5= 3
0 – 999 meters/hour, feet/hour
0 – 999 meters, feet
Hours and minutes
0,6 – 2000 RPM
3 batteries 1,5V version AA
3000 irrigation hours
0-70°C
72x72 frontal, 60 depth
IP65
68x68 mm
EEC 2004/108
Ø12x40, threaded case M12x1
PVC Ø4 length 2 meters
0-80°C
IP67
Rev:1.2
(default value 0)