Cres Cor RO151038 Manual de instalación, uso y mantenimiento - Página 9

Navegue en línea o descargue pdf Manual de instalación, uso y mantenimiento para Horno Cres Cor RO151038. Cres Cor RO151038 12 páginas. 2kw rethermalizer

5925 Heisley Road • Mentor, OH 44060-1833
IF THE RETHERMALIZER TURNS ON:
PROBLEM
Unit does not heat, or doesn't heat
properly
Blowers do not operate
Heater will not shut off
Vent fans do not shut off
Vent fans do not operate (See Note)
Control will not switch from "COOK" to
"HOLD" (timed mode)
Control will not switch from "COOK" to
"HOLD" (probe mode)
Control will not switch to "COOK" (probe
mode)

ERROR CODES:

CODE DISPLAYED
no p
Err0
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement
of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers .
Instructions for replacing parts are included in replacement parts list .
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE (continued)
POSSIBLE CAUSE
1. Sensor
2. Heater contactor
3. Loose wiring at heater contactor
4. Unit control
5. High Limit
1. Blower
2. Retherm control
1. Control defective
2. Heater contactor
1. Vent fan switch defective
2. Control compartment is still hot.
1. Vent fan switch defective
2. Vent fan defective
1. Unit is in "PROBE" mode.
2. Unit control defective
1. Unit is in the "TIMED" mode
2. Probe not plugged in
3. Probe defective
4. Unit control defective
1. Unit in "TIMED" mode
2. Probe temperature setting lower
than probe temperature
3. Probe not plugged in
4. Unit control defective
CAUSE
No meat probe
Temp probe bad
FL-CO151027
Rethermalizer
Rev. 1 (1/16)
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
1. Replace
2. Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heater will not shut off"
1. Replace
2. Replace
1. Cancel recipe and switch to "TIMED" mode
2. Replace
1. Cancel recipe and switch to "PROBE" mode
2. Plug in probe
3. Replace
4. Replace
1. Switch to "PROBE" mode
2. Set probe temperature to desired
temperature
3. Plug in probe
4. Replace
SOLUTION
Plug in probe
Replace
Page 9 of 12