7.
INPUTS/OUTPUTS TEST (TEST)
In order to have access to the test function it is necessary to enter the password 273.
In the inputs test function display3 will display the
hyphens. Every hyphen indicates one input: the input in the low position (high) indicates that the input is open
(closed).
The inputs test consists in closing the input switches and check that the display corresponds to the figure
below:
Then go to the outputs test by pressing the E key; the display3 will display
In order to enable/disable the outputs press the numerical keys indicated in the following figure: the position of
the hyphen indicates the output status; to the hyphen in the high position (low) corresponds an enabled output
(not enabled).
By pressing the E key it is possible to go back to the inputs test; in order to leave the test function, press P.
8.
SETTING OF THE NUMBER OF CYCLES TO BE CARRIED OUT (CYCL)
By number of cycles we mean the number of repetitions of the positioning programme. The automatic
functioning mode involves the possibility to repeat the selected programme. By setting a number of cycles
greater than 1, once the last dimension of the positioning programme has been carried out, at the next
command by the work counter input the positioner restarts from the first dimension of the selected programme.
data: 13/01/16
DISPLAY2
DISPLAY2
file: P1X_T_ing.doc
(Test Input) message and display2 will display 4
INPUT CLOSED
NONE
START
PRESET
PIECESCOUNTER
EMERGENCY
(Test Output).
START OUTPUT
NONE
START
FORWARD/BACKWARD
SLOW/FAST
END POSITIONING
AUX OUTPUT
KEY TO BE PUSHED
NONE
1
2
3
4
5