• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current
legislation regarding the safety laws.

Installation

Before installing the instrument, read the following warnings:
a) Connect the instrument strictly following the instructions of the manual.
b) It is the responsibility of the user to check, before using, the correct settings of the parameters of
the instrument to avoid damage to persons or things.
c) The instrument CANNOT function in a dangerous environment (inflammable or explosive).
d) The unit has sensible parts to electrostatic charge, therefore the handling of the inner electronic
cards has to be carried out with appropriate care to avoid permanent damages.
Description
The F8P is a display unit with integrated position sensor, in combination with the P50 magnetic
band, is a complete system to measure linear movements.
The display has five digits plus sign (range from -999999 up to +999999). The digits are 10mm
high to allow excellent readability also at a distance.
It is possible to select the counting direction, the number of decimal places, and the units (mm or
inches). The displayed value can be corrected with a multiplication factor, with values between
0.00001 and 999999.
The instrument can count in absolute mode or relative mode by pressing the corresponding
button. Also, it is possible to set a preset value which can be activated by pressing the
corresponding button.
The electronics are seated in a smart and strong black anodized aluminum case.
The display can be fixed quickly and easily using the two holes on the housing.
The unit is powered by a ½AA 3.6V battery which lasts approximately 4 years and when the
battery is almost exhausted, an icon will appear to advise the operator to substitute it. This does
not effect the configuration parameters and also the correct measurement is maintained if the
magnetic band is not moved during this operation.
Programming
To step into the parameter programming press key
press 2 times key
RESET
increase) and
(digit selection), set out password 0273 and confirm with
wrong set-out of password it goes out of the programming. The parameters that have to be set
can be run with key
value to be displayed for 10mm of sensor displacement,
number of decimal digits,
keys opening mode
count direction,
To enter into the modification of the selected parameter press two times
only the value) and with keys
To go out of the programming press
Value to be displayed for 10 mm of sensor displacement
This parameter together with the following allows the programming of the value on the display for
a certain displacement of the sensor. It means that is necessary to set the value which has to be
displayed corresponding to a displacement of the sensor on the magnetic band of 10mm.
The Factory value is
VISUAL
millimetres with decimal resolution.
Data: 13/01/16
and appear 4 zeroes, the first on the right is blinking, with keys
and in order of appearance they are:
and
set the wanted value to be confirmed with
.
=10.0, which is the necessary value to read the displacement in
and on the display appears
F8P_ing.doc
F8P
, now
(digit
. In case of
RESET
(one time displays
RESET
.
RESET