When an Ethernet interface joins a EtherChannel, the following interface level parameters are disabled:
bandwidth
delay
duplex
flowcontrol
ip
ipv6
mac
priority-flow-control
service-policy
spanning-tree
speed
storm-control
Fibre Channel Port Shutdown
The following table describes the changes to the interface shutdown command syntax.
4.0(0)-based
releases
4.0(1a)N1(1a)
Upgrade
Downgrade
Switched Port Analyzer (SPAN)
The following table describes the changes to SPAN sessions.
4.0(0)-based
releases
4.0(1a)N1(1a)
Upgrade
Downgrade
OL-16601-01
Set bandwidth informational parameter
Specify interface throughput delay
Enter the port duplex mode
Configure interface flowcontrol
Configure IP features
Configure IPv6 features
MAC configuration commands
Configure interface priority-flowcontrol
Configure QoS service policy
Spanning Tree Subsystem
Enter the port speed
Configure Interface storm control
The system default switchport shutdown command causes all Fibre Channel ports,
virtual or physical, to default to shutdown.
The system default switchport shutdown command now configures the
administrative state for all Ethernet ports as down. To configure the Fibre Channel
ports to shutdown state, use the system default switchport shutdown san command.
Ethernet ports will default to shutdown instead of Fibre Channel ports.
This capability needs to be reconfigured after the downgrade. Otherwise, the switch
will flag the system default switchport shutdown san command as invalid.
The default is to keep session in an open state. To shut a session, use the following
command:
switch(config)# monitor session session-number suspend
The default is to keep session state shut. To open a session, use the following
command:
switch(config)# no monitor session session-number shut
Note
The syntax of the command has also changed. The suspend keyword has been
changed to shut.
SPAN session will be in shut state after the upgrade.
If you do not execute a specific shut or no-shut command on the SPAN session, the
SPAN session will be in a no suspend state after the downgrade.
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a)
Release 4.0(1a)N1(1a) Upgrade and Downgrade Issues
7