Resolved Caveats—Cisco NX-OS Release 4.0(1a)N1(1)
This section lists the resolved caveats for this release.
OL-16601-01
Workaround: Before downgrading to the Cisco NX-OS 4.0(1a)N1(1) release, remove rules from
the roles configuration such that a role does not have more than 67 rules.
CSCsv55655
Symptom: The Cisco Nexus 5000 Series switch Ethernet port is configured in the 1 G mode of
operation using the speed 1000 command. It does not advertise and auto-negotiate the flow control
configuration. As a result, the link peer does not learn about the capabilities of the Nexus 5000
Series switches and does not enable flow control at its end.
Workaround: Disable auto-negotiation on the link peer and enable flow control for flow control to
work over the link.
CSCsw39639
Symptom: When a rule that refers to a specific interface name (Ethernet 1/1) is entered in the role
definition CLI, the command could hang. Type Ctrl-C to return to the CLI prompt.
Workaround: Do not configure rules that refer to specific interfaces in the role definition CLI.
CSCsy09062
Symptom: This is an open caveat in 4.0(0)N1(2a) and 4.0(1a)N1(1) releases. After an upgrade or
downgrade if the show startup security command is issued before performing a copy
running-config startup-config, the security process could crash.
Workaround: You can avoid a core dump by issuing a copy running-config startup-config
command after an upgrade or downgrade and before issuing the show startup <feature> command.
CSCsy08516
Symptom: This is an open caveat in 4.0(0)N1(2a) and 4.0(1a)N1(1) releases. After an upgrade or a
downgrade and when the system comes up, users are assigned a network-operator role by default.
Workaround: To avoid the problem, reload the switch after an upgrade or a downgrade and after
the system comes up. You can then perform the copy running-config startup-config operation to
save the correct configuration.
CSCsy37432
Symptom: This is an open caveat in the Cisco NX-OS 4.0(0)N1(2a) release. On the 4.0(0)N1(2a)
release if an RBAC role has more than 35 rules configured, show running-config and copy
running-config cause the vshd process to core dump.
Workaround: Before downgrading to the Cisco NX-OS 4.0(0)N1(2a) release, remove rules from
the roles configuration such that a role does not have more than 35 rules.
CSCsy53275
Symptom: This is an open caveat in the Cisco NX-OS4.0(0)N1(2a) release. If there are 20 RBAC
roles configured with 20 rules each, the RBAC feature becomes non-functional.
Workaround: Do not configure more than 20 rules in each role. The feature works fine if the
numbers of rules are limited to 10 per role.
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a)
Caveats
19