Select the Advanced Settings tab on the Express Setup screen. The Advanced Settings screen
Step 9
appears (Figure 10).
Figure 10
Express Setup Advanced Settings Screen
Step 10 In the Telnet Access field, click Enable if you are going to use Telnet to manage the switch
module by using the CLI. If you enable Telnet access, you must enter a Telnet password.
Step 11 In the Telnet Password field, enter a password. The Telnet password can be from 1 to 25
alphanumeric characters, is case sensitive, allows embedded spaces, but does not allow spaces
at the beginning or end. In the Confirm Telnet Password field, re-enter the Telnet password.
Step 12 In the SNMP field, click Enable to enable Simple Network Management Protocol (SNMP).
Enable SNMP only if you plan to manage switch modules by using CiscoWorks 2000 or
another SNMP-based network-management system.
Step 13 If you enable SNMP, you must enter a community string in the SNMP Read Community field,
the SNMP Write Community field, or both. SNMP community strings authenticate access to
MIB objects. Embedded spaces are not allowed in SNMP community strings. When you set
the SNMP read community, you can access SNMP information, but you cannot modify it.
When you set the SNMP write community, you can both access and modify SNMP
information.
Step 14 In the System Contact field, enter the name of the person who is responsible for the switch
module. In the System Location field, enter the wiring closet, floor, or building where the
switch module is located.