Range test
FIBARO Smoke Sensor has a built-in Z-Wave network main controller's range tester.
To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test
only in special cases.
Follow the below instructions to test the main controller's range:
1. Press and hold the B-button
2. Wait for the visual indicator to glow white and short acoustic signal to sound
3. Release the B-button
4. Wait for the visual indicator to glow violet
5. Press the B-button again, briefly
6. Visual indicator will indicate the Z-Wave network's range (range signalling modes described below)
7. To exit Z-Wave range test, press the B-button briefly
Z-Wave range tester signalling modes:
Visual indicator pulsing green – Smoke Sensor attempts to establish a direct communication with the main controller. If a direct communication attempt fails, the
device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow.
Visual indicator glowing green – Smoke Sensor communicates with the main controller directly.
Visual indicator pulsing yellow – Smoke Sensor tries to establish a routed communication with the main controller through other modules (repeaters).
Visual indicator glowing yellow – Smoke Sensor communicates with the main controller through the other modules. After 2 seconds the device will retry to establish
a direct communication with the main controller, which will be signalled with visual indicator pulsing green.
Visual indicator pulsing violet – Smoke Sensor does communicate at the maximum distance of the Z-Wave network. If connection proves successful it will be
confirmed with a yellow glow. It is not recommended to use the device at the range limit.
Visual indicator glowing red – Smoke Sensor is not able to connect to the main controller directly or through another Z-Wave network device (repeater).
Note: Communication mode of the Smoke Sensor may switch between direct and one using routing, especially if the device is on the limit of the direct range.
Fire detection
FIBARO Smoke Sensor responds to the physical presence of a smoke. The device checks every 10 seconds for a smoke. Once the level of smoke exceeds value
set in advanced parameter 1, Smoke Sensor triggers an alarm.
Optical smoke detector used in FIBARO Smoke Sensor has 3 levels of sensitivity, compliant with EN 14604:2005. By default, the detector is set to the middle
sensitivity level. Sensitivity level depends on the parameter 1 settings (modified only through the main Z-Wave controller).
Fire alarm is signaled by:
sending an appropriate alarm command to the Z-Wave controller
sending an appropriate alarm command to associated devices
intermittent sound
visual indicator blinking red
Once the fire alarm has ceased, the sensor checks whether the smoke has actually disappeared before getting back to normal operation, i.e. performing a self test
each 10 seconds and checking for presence of smoke.
Note: FIBARO Smoke Sensor is a multiple use device, however, for greater safety, it is recommended to replace the device with a new one after a fire occurrence.
Note: If fire alarm is triggered, but the level of smoke did not exceed concentration equal to three times of the sensitivity set in parameter 1 (the individual levels of
sensitivity are printed on the device casing), user can mute sound alarm by holding the B-button (temporarily reducing the sensor's sensitivity).
Note: Visual indicator will still indicate an alarm state by blinking red. If smoke level concentration is greater than three times of the sensitivity set in parameter 1,
mute will automatically turn off and the device will alarm fire again (using visual and audible indicator).
Excess temperature detection
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGSD-002