FIBARO FGDW-002 Manual de instrucciones - Página 8

Navegue en línea o descargue pdf Manual de instrucciones para Sensores de seguridad FIBARO FGDW-002. FIBARO FGDW-002 16 páginas. Door/window sensor
También para FIBARO FGDW-002: Manual de instrucciones (16 páginas)

FIBARO FGDW-002 Manual de instrucciones
8
i
NOTE
Opening the casing
may result in trigger-
ing an alarm. To avoid
it, remove the asso-
ciations for the 3rd
group.
i
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. Use
reset procedure only
if the primary con-
troller is missing or
inoperable.
Certain
device removal can be
achieved by the pro-
cedure of removing
described in "Adding/
removing the device"
on page 5.
OPERATInG THE DEVICE
Resetting the Door/Window Sensor 2:
Reset procedure allows to restore the device back to its factory set-
tings, which means all information about the Z-Wave controller and
user configuration will be deleted.
In order to reset the device:
1. Open the cover.
2. Remove the battery.
3. Install the battery while holding both TMP buttons.
4. Release the TMP button within 5 seconds.
5. Visual indicator will blink 3 times to confirm launching of reset
procedure.
6. Wait around 30s for the resetting process to end, do not remove
the battery.
7. Visual LED indicator will blink 6 times to confirm the reset.
Replacing the battery:
In FIBARO Home Center controller current battery level is displayed
in the interface. If a battery icon turns red, it means the battery needs
replacement.
Notification report:
The device uses notification Command Class to report different
events.
notification Type
Home Security
Access Control
Access Control
Power Management
Heat Alarm
Heat Alarm
Triggering Event
Tampering, product covering
removed
Door/window opened
Door/window closed
Replace battery now
Overheat detected, unknown
location
Underheat detected, unknown
location