DEFAULT SETTINGS
SETTING
[display]
REMOTE INPUT 1
RMIMP1
TIMER,
COUNTER
TMRCTR
DRIVE RATIO
DRATIO
TESTING THE SYSTEM
1. With power applied to the circuit the Rotation Counter Status LED, as shown in Figure 3, will turn "On"
when the Rotation Counter Sensor is aligned with the steel target.
2. Continue to slowly turn the target away from the Sensor. If the sensor LED stays "On", move the Sensor
away from other metal objects. The target should light the Sensor Status LED only wither when PTO is
spinning, or when the target is directly in line with Sensor as shown in Figure 3.
3. Press TIMER/COUNTER.
4. Enter 20 (The number of rotations to count.)
5. Press TIMER/COUNTER
6. Indicator should display 20 REV
7. Engage PTO
8. Watch display to determine if the display counts down from 20.
9. Disengage PTO
10. Press CLEAR
IMPORTANT: Failure to install this system properly could result in Sensor and equipment damage. Please read
this document thoroughly before engaging PTO.
IMPORTANT: Failure to keep sensor clear of dirt and debris could result in sensor and equipment damage.
The installation diagrams show safety shields removed in order to show additional details. Never
operate equipment without safety shields in place. Adding the target to a rotating shaft may require additional
shielding and is not provided. Consult your original equipment manufacturer.
D4044
Rotation Counter Installation Manual for EZ/TMR xx10 Series Indicators
OPTIONS [displayed]
D.A.N NO.
BOLD=DEFAULT
MENU 5. CONTROL SETTINGS
1401
TARE, PRINT, HOLD,
(402)
NETGRS, M+, ZERO,OFF,
PRESET, SWITCH, MIXCTR
TIMER, COUNTER
4301
(421)
1.0
4302
(422)
DESCRIPTION
Set function of Remote Input line.
Change to MIXCTR when utilizing
Rotation Counter.
Select Time or Mixer Revolutions
to decrement mix
TIMER/COUNTER. Change to
COUNTER when utilizing
Rotation Counter.
Unless directly measuring mixer
rotor or auger (1:1), enter the
number of input pulses that equal
1 revolution of the rotor or auger.
(Example: If 1000 RPM Tractor
PTO speed equals 20 RPM of the
mixing auger make this setting
50.0)
Default Settings
9