Digital Acoustics ii3-ESS Manual del usuario - Página 11
Navegue en línea o descargue pdf Manual del usuario para Altavoces Digital Acoustics ii3-ESS. Digital Acoustics ii3-ESS 18 páginas. Ip speaker system
Connections and Controls
Speaker Connection
To connect an 8 Ohm load to the ii3-ESS, connect two wires from the
speaker terminals (or 8 Ohm load source) to one of the supplied
terminal block plugs and insert it into the Speaker connector on the
ESS. Speaker connections are polarity independent.
Power Supply / Amplifier
The ii3-ESS supports Power over Ethernet (PoE - 802.3af compatible)
or can be powered externally from an external 24V AC/DC 40 Watt
power supply. Note that if using PoE, that the Power Source Equipment
(PSE) must be capable of supplying the maximum of 15.4 Watts for
each ii3-ESS that is connected to it.
Two amplifier settings are available. The low setting is 7.5 watts and
the high setting is 20 watts. When using PoE, the low amplifier setting
must be used. When using an external power supply, either the high
or low setting can be used.
Before powering up the ii3-ESS, the jumpers for the Power Supply and
Amplifier must be set in the correct position. The Jumpers consist of 5
columns of 2 pins located on the side of the unit labeled as Amp
Setting.
For PoE, the jumpers must be set as follows:
• Two Horizontal jumpers on columns 1 and 2 indicate PoE
(802.3af compatible) is supplied via the RJ-45 cable
• One Vertical jumper on column 4 indicates Low Amplifier setting
For External Power and high amp setting, the jumpers are set as
follows:
• Two Horizontal Jumpers on columns 2 and 3 indicate External
power is supplied
• One Vertical jumper on column 5 indicates High Amplifier setting
8