Audio Inputs:
·
Two XLR connectors, a female and a male, allow either unbalanced monaural or unbal-
anced stereo audio input.
·
Four (4) AES/EBU digital audio (program in) switched 110 ohm female XLR
·
Configurable sample rate of 44.1KHz or 48KHz
·
AES/EBU inputs are failsafe bypassed to outputs in the event of power failure.
Audio Outputs:
·
Four (4) AES/EBU digital audio (program out) switched 110 ohm male
Audio Frequency Response
·
0 to 20 KHz, -3 dB
LAN Interface: TCP/IP Ethernet
·
Standard: One (1) 10/100 BASE-T RJ45
·
Assignable IP addressing either fixed or DHCP (unit ships fixed at (192.168.001.002)
GPO's (General Purpose Outputs):
·
Four (4) [One (1) per channel] Form C relays with Normally Open (NO) and Common
(C) outputs rated .5A @200VDC
·
10-pin detachable terminal strip
GPI's (General Purpose Inputs)
.
Master switch GPI
·
Four independent GPI contacts, one for each AES section
Front Panel
·
Green power status lamp
Physical Attributes
·
19.0" W x 12.0" D x 1.75" H (1RU EIA rackmount)
Power Requirements
·
Input 90 -240 VAC @ .5 amps (25 Watts)
·
Standard IEC power cord
Weight
·
7 lbs

Specifications

Controls: