ActronAir ECOFLEX MINI VRF R-32 Series Manual del usuario - Página 13
Navegue en línea o descargue pdf Manual del usuario para Aire acondicionado ActronAir ECOFLEX MINI VRF R-32 Series. ActronAir ECOFLEX MINI VRF R-32 Series 20 páginas. Four-way compact cassette
También para ActronAir ECOFLEX MINI VRF R-32 Series: Manual del usuario (20 páginas), Manual del usuario (20 páginas), Manual del usuario (20 páginas), Manual del usuario (20 páginas), Manual del usuario (20 páginas)
Owner's Manual
Normal Phenomena that Are Not Air Conditioner Faults
The following phenomena are normal during operation of the air conditioner. They can be solved according to the
instructions below or do not need to be solved.
The Indoor Unit emits
white mist
The Indoor Unit blows
dust
The Indoor Unit emits
odor
Water drips on the air
conditioner surface
"Self-cleaning" sound of
icing
The air conditioner makes
low noise
Switching from cooling/
heating (not available for
cooling only units) mode
to fan only mode
In winter, the outdoor
temperature is low, and
heating effects may be
decreased
No heating or cooling
options
1. In an environment where the indoor relative humidity is too high, when the Indoor Unit
runs in cooling mode, white mist may appear due to the humidity and the temperature
difference between the air inlet and outlet.
2. When the air conditioner is switched to heating mode after defrosting, the Indoor Unit
discharges the moisture generated from defrosting as steam.
When the air conditioner has not been used for a long time or is used for the first time, the
air filter should be cleaned. Otherwise, dust that has entered the Indoor Unit will be blown
out.
The Indoor Unit absorbs the odors of rooms, furniture or cigarettes, etc., and disperses the
odors during operation. It is advised to have the air conditioner cleaned and maintained
regularly by professional technicians.
When the indoor relative humidity is high, it is normal for condensation or slight water
blowing to occur on the surface of the air conditioner.
During self-cleaning, there may be a slight clicking sound for about 10 minutes, indicating
that the Indoor Unit is freezing, which is normal.
1. When the air conditioner is in "Auto", "Cool", "Dry", and "Heat" modes, it may emit a
low continuous "hissing" sound, which is caused by the refrigerant flowing between the
Indoor Unit and the Outdoor Unit.
2. A "hissing" sound may be heard for a short time after the air conditioner stops operation
or during "defrosting", which is caused when the refrigerant stops flowing or changes its
flow.
3. When the air conditioner is in Cool mode or Dry mode, a small and continuous rustling
sound can be heard, which is caused by the drain pump.
4. When the air conditioner starts or stops running, you may hear a squeaking sound which
is produced by the expansion or shrinkage of parts or surrounding aesthetic materials
due to temperature change. The sound will disappear when the air conditioner is
running normally.
When the Indoor Unit reaches the set temperature, the air conditioner compressor
automatically stops operation and switches to the fan only mode. When the room
temperature rises (in cooling mode) or falls (in heating mode) to a certain level, the
compressor is restarted and cooling or heating operation is resumed.
1. During the heating operation of the heat pump type air conditioner, the air conditioner
absorbs heat from the outdoor air and releases it to heat the indoor air. This is the heat
pump heating principle of the air conditioner.
2. When the heat pump runs in heating mode, the Outdoor Unit blows out cold air, causing
the outdoor temperature to drop. When the outdoor temperature is extremely low, the
heating capability of the air conditioner drops gradually. You are advised to use other
heating devices for heating.
All Indoor Units in the same air conditioning system can only operate in the same mode, for
example, cooling, heating, or others. Conflict may occur is Indoor Units are set to different
modes. Only the Indoor Unit that is first started up can determine the operating mode, and
those started after it can only follow the operating mode of the first Indoor Unit. To change
the operating mode, you need to turn off all the Indoor Units. The operating mode of all
Indoor Units must be the same.
Owner's Manual ECOFLEX MINI VRF R-32 SERIES - 4 WAY COMPACT CASSETTE
Doc. No.9590-4028-05 Ver. 1 230821
ECOFLEX MINI VRF R-32 SERIES
13