Installing Device
2.2 Connecting Power
To mount the device to a panel, do the following:
1.
Place the device against the panel and align the adapters with the mounting
holes.
Figure 2.3
2.
Install the supplied screws to secure the adapters to the panel.
2.2

Connecting Power

The RUGGEDCOM RS1600 supports single or dual redundant high AC, high DC and/or
low DC power supplies. The use of two power modules is recommended to provide
redundancy and load balancing.
The RUGGEDCOM RS1600 can be equipped with either a screw-type or pluggable
terminal block, which provides power to both power supplies. The screw-type
terminal block is installed using Philips screws and compression plates, allowing
either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable connections under severe shock or vibration.
IMPORTANT
For maximum redundancy in a dual power supply configuration, use two
independent power sources.