Characteristics of the programming interface
Blue
Communication between programming interface and RTLS Locating Manager
Green
Communication between RTLS Locating Manager and RTLS408xT
Red
Communication between RTLS Locating Manager and RTLS408xT
All RPC calls (Remote Procedure Call) received by the programming interface are answered
immediately. This means that there is no need to wait for an acknowledgment of the RPC call
until the data transfer is completed. The completion of the data transmission is confirmed by
an event message provided for this purpose. The various event messages can be found in the
section "Event messages (Page 20)".
The positive acknowledgment of an RPC call does not guarantee or indicate successful
transmission and display of new display contents on the transponder. This can happen if, for
example, the transponder was switched off during this time or is not within radio range.
SIMATIC RTLS4083T
Operating Instructions, 08/2021, C79000-G8976-C646-02
3.2 Communication via the programming interface
Programming interface
17