Technical specifications
4.1
RTLS4083T technical specifications
Table 4- 1
Technical specifications of the transponder RTLS4083T
Product name
PULSE radio frequencies (localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
PHASE radio frequencies (communication and optional localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
Supply voltage
Supply voltage
Service life (at 20 ℃)
SIMATIC RTLS4083T
Operating Instructions, 02/2022, C79000-G8976-C527-06
SIMATIC RTLS4083T
IEEE 802.15.4-2015 UWB HRP PHY
850 Kbps
3993.6 MHz (UWB channel 2; CE, FCC, NOM)
6489.6 MHz (UWB channel 5; CE, NOM, CMIIT, ISED)
499.2 MHz
3100 MHz ... 4800 MHz (CE, FCC/NOM)
6000 MHz ... 7000 MHz (CE, NOM, CMIIT, ISED)
0.037 mW (-41.3 dBm/MHz)
Maximum 30 m
0.2 m
Built-in UWB antenna
IEEE 802.15.4
1 Mbit/s
2405 MHz ... 2480 MHz
2 MHz; data transmission on 802.15.4; channels
configurable
2400 MHz ... 2483.5 MHz
0.00025 mW ... 4 mW (configurable)
Maximum 50 m
1 m
Built-in 2.4 GHz antenna
3.7 V lithium ion rechargeable battery (1900 mAh)
Standby: 1 year
Operation: 100% UWB localization at 1 second: 6 months
Display updates every 10 seconds without localization:
25 days
6GT2700-5DC23, 6GT2700-5DC33
4
17