Siemens SIMATIC RTLS4084T Manual de instrucciones - Página 18

Navegue en línea o descargue pdf Manual de instrucciones para Equipamiento industrial Siemens SIMATIC RTLS4084T. Siemens SIMATIC RTLS4084T 35 páginas. Localization systems
También para Siemens SIMATIC RTLS4084T: Manual de instrucciones (23 páginas)

Siemens SIMATIC RTLS4084T Manual de instrucciones
Programming interface

3.4 Event messages

Command "Get Display Theme"
This command outputs the current "theme" and the current texts and codes for a single
transponder. Only completely transmitted texts are returned. If the current "ThemeID" is
unknown, it has the return value -1.
URI
Parameter
Return value
3.4
Event messages
General
The event messages and their parameters are described below.
"Display Theme Changed" event message
This event message is sent after a "Theme" on the display has been changed. If the text
transmission has failed, the value "-1" is set in the "ThemeID" parameter, which invalidates
the parameter.
URI
Parameter
"Display Text Changed" event message
This event message is sent after the contents of a form field on the display have been
changed. Text is the content of this form field. If the text is empty, a problem with setting the
text occurred.
URI
Parameter
18
"agilion.wls.epaper.get_display_theme"
TransponderID, type: UInt64
Consists of:
Result, type: UInt32
ThemeID, type: UInt32
Field with the following parameters:
FieldID, type: UInt32
Text, type: String
"agilion.wls.epaper.display_theme_changed"
Consists of:
TransponderID, type: UInt64
ThemeID, type: UInt32
"agilion.wls.epaper.display_text_changed"
Consists of:
TransponderID, type: UInt64
FieldID, type: UInt32
Text, type: String
Operating Instructions, 04/2021, C79000-G8976-C626-02
SIMATIC RTLS4084T