Mounting the device
3.1 Preparing for installation
3.1.4
Notes on installation
Mounting cutout
The HMI device can be installed in control cabinets (see table for material thickness). No
special tools are required for mounting. The HMI device can be operated both in landscape
and portrait format with a vertical inclination of up to +/-35°. Due to the surrounding beveling
of the stainless steel front of 45°, liquids are able to drain off even in an inclined installation
position of +/-35°.
The following conditions apply to the mounting cutout:
The front material has to consist of sheet steel or material of a strength that corresponds to
at least the stability of sheet steel.
Mounting cutout
Material thickness
Permitted deviation from plane
This condition must be fulfilled for the mounted HMI device.
Permitted surface roughness in the area of the mounting seal
3.1.5
Checking clearances
The following figure shows the clearances during mounting of the HMI devices in horizontal
and vertical format for sufficient self-ventilation of the devices:
①
②
x
y
z
Note
Ensure that the maximum ambient temperature is not exceeded when mounting the device
in a cabinet and especially in a closed enclosure.
22
Clearance for installation in landscape format
Clearance for installation in portrait format
Distance from wall at least 23 cm.
At least 50 mm distance
At least 10 mm distance
Compact Operating Instructions, 05/2018, A5E38804191-AA
Dimensions
1.5 to 6 mm
≤ 0.5 mm
≤ 120 µm (R
120)
z
Comfort Panels INOX PCT