Siemens SIMOGEAR 2730 Instrucciones de montaje y funcionamiento - Página 40

Navegue en línea o descargue pdf Instrucciones de montaje y funcionamiento para Equipamiento industrial Siemens SIMOGEAR 2730. Siemens SIMOGEAR 2730 48 páginas. Geared motor with rotary encoder for safety-relevant applications

Ensuring functional safety
4.5 Technical data
21
22
23
24
25
26
27
28
4.5.3

Technical specifications of the brake for encoders for functional safety

The guide values for switching times required for rated operation of the holding brake can be
found in Catalog D50.1 (Chapter 11). These switching times may change as a result of actual
operating conditions and must then be adjusted accordingly.
NOTICE
Air gap check
Air gap check by operator only possible with force-ventilated motors.
NOTICE
Working on the brake
Only Siemens service personnel or personnel trained and authorized by Siemens may carry out
the work on the brake.
Note
L brakes can also be implemented as functionally safe LS brakes (C09). On this topic, carefully
review operating instructions BA 2332 SIMOGEAR geared motor with holding brake for safety-
related applications.
Brake type
L4 (06E)
38
Circuit, circuit symbols according to DIN EN 60617 Part 6 / IEC 60617-6
Rated current I
 in A
N
Power factor cos φ
Rated power P
 in kW
N
Rated speed n
 in rpm
N
Energy efficiency
Gearbox code for SINAMICS systems
Encoder code for SINAMICS systems
Rated braking tor‐
que T
br
at 100 rpm
Nm
1.4
2
3
4
5
Working capacity
Nominal air gap s
until the maxi‐
mum air gap W
is
V
reached
MJ
mm
46.8
0.2
46.8
0.2
39.6
0.2
36
0.2
23.4
0.2
Operating Instructions, 01/2024, A5E53220857A/RS-AA
Maximum
LN
air gap s
mm
0.65
0.6
0.55
0.5
0.4
SIMOGEAR functionally safe rotary encoder
Lmax