Siemens SITRANS WFS300 Manual de instrucciones - Página 33

Navegue en línea o descargue pdf Manual de instrucciones para Equipamiento industrial Siemens SITRANS WFS300. Siemens SITRANS WFS300 42 páginas. Sensing heads

Siemens SITRANS WFS300 Manual de instrucciones

Technical specifications

9.1

Performance

Operating range
Particle size
Product temperature
Accuracy
Repeatability
9.2

Construction

Construction
Mounting
Damping fluid
Enclosure
LVDT conditioner
card
enclosure
Sensor type
Sensing plate
Cable
for connection between conditioner card and
integrator
33
minimum
0.2 t/h (0 to 0.2 STPH)
maximum
40 t/h (0 to 44 STPH)
fine powder to 13 mm (0.5")
-40 to +232 °C (-40 to +450 °F)
± 1 % of full scale, higher accuracy with linearizing function of integrator
Accuracy subject to: on factory approved installations the flowmeter system's totalized weight will
be within the specified accuracy when compared to a known weighed material test sample. The
test rate must be within the specified range of the design capacity and held constant for the dura-
tion of the test. The minimum material test sample must be equivalent to a sample obtained at the
test flow rate for at least ten minutes running time.
± 0.2 %
dust-tight cast aluminum frame with fiberglass rear cover
Option: epoxy painted external aluminum casting surfaces
Side mount or base mount (to suit application)
1 - 100 cm
/s (100 - 10,000 cs) silicone (Dow Corning 200 recommended)
2
IP64 (per IEC 60529)
NEMA / Type 4 / IP65 (remote mounted unit)
LVDT (linear variable differential transformer)
construction
304 (1.4306) stainless steel
Options
Belden
20 AWG (0.5mm
Belden 9260, 6 conductor
(0.5 mm
316 (1.4404) stainless steel
abrasion resistant lining
PTFE coating for low cohesion and low friction
8404, 4 conductor, shielded
®1
) or equivalent
2
, shielded 20 AWG
2
) or equivalent
2
Operating Instructions, 03/2021, A5E32880243-AC
9
150 m (500 ft) maxi-
mum
300 m (1000 ft) max-
imum
SITRANS WFS300