También para Siemens SX Series: Instrucciones de uso (38 páginas), Manual de instrucciones (38 páginas), Manual de instrucciones (42 páginas), Manual de instrucciones (42 páginas), Manual de instrucciones (44 páginas), Manual de instrucciones (46 páginas), Manual de instrucciones (44 páginas), Manual de instrucciones (42 páginas), Manual de instrucciones (40 páginas), Manual de instrucciones (42 páginas), Manual de instrucciones (44 páginas), Manual de instrucciones (40 páginas)

Siemens SX Series Manual de instrucciones
en Fault, what to do?
3

Fault, what to do?

Experience has shown that you can
o ?
F a u l t , w h a t t o d
rectify most faults which occur in daily
operation yourself. This ensures that the
appliance is quickly available to you
again. In the following overview you can
find possible causes of malfunctions
and helpful information for rectifying
them.
If the appliance stops during
Note:
dishwashing or does not start for no
obvious reason, first run the Abort
programme function (Reset)
~ "Operating the appliance"
on page 28.
:
Warning
Improper
repairs or use of non-original spare
parts may cause considerable damage
and put the user at considerable risk!
Always have repairs carried out by
technicians. If a component has to be
replaced, always use original spare
parts.

Waste water pump

Large food remnants or foreign objects
which were not captured by the filters
may block the waste water pump. The
rinsing water will then be above the
filter.
:
Warning
Danger of cutting!
Sharp and pointed objects or glass
fragments may block the waste water
pump.
Always carefully remove foreign objects.
34
Clean the waste water pump as
follows:
Disconnect the dishwasher from the
1.
power supply.
Take out top basket 12 and bottom
2.
basket 1j.
Remove the filters 1Z.
3.
Scoop out water, use a sponge if
4.
required.
Prise off the pump cover (as shown)
5.
using a spoon. Grip the pump cover
by the crosspiece and lift diagonally
inwards (1). Remove cover
completely.
Check impeller wheel and remove
6.
any foreign objects.
Place pump cover in the original
7.
position (2) and press down until it
engages (3).
Install filters.
8.
Re-insert baskets.
9.