Ricoh A183 Boletín técnico - Página 7

Navegue en línea o descargue pdf Boletín técnico para Impresora Ricoh A183. Ricoh A183 19 páginas.

RICOH
Model:
Skylark
- Reasons for correction -
1. SP56 (ADS Adjustment) should not be performed by itself. It should be performed as a
part of the procedure starting from cleaning the optics.
2. By performing SP56, the image density with ADS compared from the center notch
(manual ID) may become lighter, but will not become darker. So, if dirty background
occurs only in ADS mode, the standard image density may be out of specification.
3. Since SP56 is used to memorize the adjustment standard value, not for output value
checking, the words "If the ADS voltage is not within +-0.2 volts of the standard voltage
(2.5V) " has been eliminated.
T
B
echnical
ulletin
Date:
15-Apr-97
PAGE: 3/3
No:
4