Cisco 2691 Series Manual de inicio rápido - Página 12

Navegue en línea o descargue pdf Manual de inicio rápido para Enrutador de red Cisco 2691 Series. Cisco 2691 Series 29 páginas. Modular routers
También para Cisco 2691 Series: Instalación y formato (34 páginas), Ficha de datos (8 páginas), Manual del usuario (48 páginas)

Cisco 2691 Series Manual de inicio rápido

Installing on Desktop

Caution
If you place the Cisco router on a desktop, do not place anything that weighs more than 10 pounds (4.5 kilograms)
on top of the chassis.

Grounding the Chassis

You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical
safety standards.
• For NEBS-compliant grounding, use size AWG 6 (13 mm
• For NEC-compliant grounding, use size AWG 14 (2 mm
• For EN/IEC 60950-compliant grounding, use size AWG 18 (1 mm
terminal.
To connect the chassis to a reliable earth ground, perform the following steps:
Strip one end of the ground wire to the length required for the ground lug or terminal.
Step 1
• For the NEBS ground lug—approximately 0.75 in. (20 mm)
• For user-provided ring terminal—as required
Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size.
Step 2
Attach the ground lug or ring terminal to the chassis as shown in Figure 6 or Figure 7. For the ground lug, use the two
Step 3
screws with captive locking washers provided. For a ring terminal, use one of the screws provided. Use a number 2
Phillips screwdriver, and tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).
Connect the other end of the ground wire to a grounding point at your site.
Step 4
Figure 6
NEBS-Compliant Chassis Ground Connection Using Ground Lug
AS YN C
31
27
30
29
26
AS YN C
25
24- 31
28
24
23
19
22
15
21
18
14
11
17
20
13
10
AS YN C
16
9
8-1 5
12
8
7
6
3
2
5
4
1
0
Ground lug
attachment
Figure 7
Chassis Ground Connection Using Ring Terminal
AS YN C
31
30
27
26
29
AS YN C
25
24- 31
28
24
23
22
15
21
14
11
20
10
13
AS YN C
8-1 5
12
9
8
7
6
5
4
Ring terminal
attachment
12
AS YN C
16- 23
AS YN C
0-7
SEE MAN
UAL BEF
DS U
ORE INS
EN
TAL LAT ION
56K
ACT
100 Mbp
SEE MAN
s
UAL BEF
ORE INS
LINK
ACT
CF1
100 Mbp
s
FAS T ETH
ERN ET
LINK
0/1
FAS T ETH
ERN ET
0/0
19
18
AS YN C
16- 23
17
16
3
2
AS YN C
1
0-7
0
SEE MAN
UAL BEF
ORE INS
DS U
EN
TAL LAT ION
56K
ACT
100 Mbp
SEE MAN
s
UAL BEF
ORE INS
LINK
ACT
CF1
100 Mbp
s
FAS T ETH
ERN ET
LINK
0/1
FAS T ETH
ERN ET
0/0
2
) wire and the ground lug provided in the accessory kit.
2
) or larger wire and an appropriate user-supplied ring terminal.
2
) or larger wire and an appropriate user-supplied ring
DS U
TAL LAT ION
56K
SEE MAN
UAL BEF
ORE INS
TAL LAT ION
CI SC O 26
91
CON SOL
E
AUX
DS U
TAL LAT ION
56K
SEE MAN
UAL BEF
ORE INS
TAL LAT ION
CI SC O 26
91
CON SOL
E
AUX