Cisco SGE2000 Nota de publicación - Página 3

Navegue en línea o descargue pdf Nota de publicación para Enrutador de red Cisco SGE2000. Cisco SGE2000 16 páginas. Nx-os fabric extender
También para Cisco SGE2000: Manual de instalación rápida (32 páginas), Ficha de datos (5 páginas), Manual de actualización del firmware (5 páginas), Manual de inicio rápido (2 páginas), Manual de configuración (46 páginas)

Cisco SGE2000 Nota de publicación
1 February 2007

Known Restrictions and Limitations

Headline
Description
The time zone setting is not applied after you upload the
System->System
configuration from the TFTP server.
Management->Time-
Recommended Workaround: After you upload the configuration
>System Time
file, change the time zone setting in the Time Zone Offset file.
There may be cases where copying a running configuration file to
a start up configuration file with saved VLAN values will issue
System -> Admin -> File
an error after an upgrade.
Management -> Save
Configuration
Recommended Workaround: Verify that you are not trying to
create the same value twice.
Cannot add users to the SNMP via the GUI.
System -> SNMP ->
Recommended Workaround: Create SNMP groups before adding
Security -> Users
users.
Deleting 3 or more SNMP communities advanced entities from
the table may result in an error "Request Entity Too Large".
System->SNMP-
>Security->Communities
Recommended Workaround: Delete one SNMP community
entity at a time.
Combo ports
MGBSX1(T) 100M SFP registers its speed as 1000M.
Admin->Diagnostics-
Cable length for Fast Ethernet Copper Ports is not displayed.
>copper ports
In a stacked configuration, running an optical test may result in
Admin->Diagnostics-
traffic lost on the GE port.
>copper ports
Recommended Workaround: Disable STP on the port.
After pressing the "Test" button, the "Advance" button is not
displayed.
Admin->Diagnostics-
Recommended Workaround: After switching to another page and
>copper ports
returning to this page, the cable length and the "Advance" button
are displayed.
System->System Mgmt-
Zoom view shows SFP ports number 1 & 2 description only. For
>Zoom
SGE2000 Only.
Linksys One Ready Communications Solution SFE2000/